Remote commands for Multi CISPR APD measurements
R&S
®
ESW-K58
81
User Manual 1179.0880.02 ─ 03
TRIGger<tp>[:SEQuence]:SLOPe
<Type>
This command selects the trigger slope.
Suffix:
<tp>
.
irrelevant
Parameters:
<Type>
POSitive
Triggers when the signal rises to the trigger level (rising edge).
NEGative
Triggers when the signal drops to the trigger level (falling edge).
*RST:
POSitive
Example:
//Select trigger slope
TRIG:SLOP NEG
Manual operation:
See
TRIGger[:SEQuence]:IFPower:HOLDoff
<Period>
This command defines the holding time before the next trigger event.
Note that this command can be used for
any trigger source
, not just IF Power
(despite the legacy keyword).
Parameters:
<Period>
Range:
0 s to 10 s
*RST:
0 s
Default unit: S
Example:
TRIG:SOUR EXT
Sets an external trigger source.
TRIG:IFP:HOLD 200 ns
Sets the holding time to 200 ns.
Manual operation:
See
OUTPut<up>:TRIGger<tp>:DIRection
<Direction>
This command selects the trigger direction for trigger ports that serve as an input as
well as an output.
Suffix:
<up>
.
irrelevant
<tp>
Selects the used trigger port.
2 = trigger port 2 (front)
3 = trigger port 3 (rear panel)
Parameters:
<Direction>
INPut | OUTPut
INPut
Port works as an input.
Configuration