R&S ESU
Storing and Loading Instrument Settings
5.36
Quick Start Guide 1302.6163.62 - 04
2. By selecting the data record from a list:
➢
Press the
FILE
key and then the
RECALL
softkey.
➢
Press the
ITEMS TO SAVE/RCL
softkey.
The list of available data records is shown.
➢
Select the data record to be loaded by using the rotary knob and confirm by pressing
ENTER
twice. The data record will be loaded.
➢
To change the instrument configuration path, use the
EDIT PATH
softkey.
5.7.2.1 Automatic Loading of a Data Record during Booting
If the R&S ESU is switched on in the factory default state, it loads the instrument settings that
it had when switched off (provided that it was switched off using the
STANDBY
switch on the
“ Switching Off the R&S ESU” on page 2.7
).
However, the R&S ESU can also automatically load a data record defined by the user. This
requires performing the following procedure:
➢
Press the
FILE
key and then the
RECALL
softkey.
➢
Press the
STARTUP RECALL
softkey.
The list of available data records is shown.
To load stored traces, use the
ITEMS TO SAVE/RCL
softkey to select
the
All Traces
field.
During loading, the R&S ESU detects which parts the called data
record contains and, if applicable, ignores any partial data records that
were selected but are not available.
Summary of Contents for esu
Page 26: ...R S ESU Contents 6 Quick Start Guide 1302 6163 62 04 ...
Page 28: ......
Page 32: ...R S ESU 0 4 Quick Start Guide 1302 6163 62 04 ...
Page 88: ...R S ESU Preparing for Use Operating System Properties 2 38 Quick Start Guide 1302 6163 62 04 ...
Page 104: ...R S ESU Basic Operation Setting Parameters 4 12 Quick Start Guide 1302 6163 62 04 ...
Page 201: ...Quick Start Guide 1302 6163 62 04 R S ESU Appendix Appendix ...
Page 202: ...Quick Start Guide 1302 6163 62 04 R S ESU Appendix ...