Remote Control
R&S
®
ESR
775
User Manual 1175.7068.02 ─ 12
ABSolute
Evaluates only limit lines with absolute power values
RELative
Evaluates only limit lines with relative power values
AND
Evaluates limit lines with relative and absolute power values. A
negative result is returned if both limits fail.
OR
Evaluates limit lines with relative and absolute power values. A
negative result is returned if at least one limit failed.
*RST:
REL
Example:
CALC:LIM:ESP:PCL:LIM ABS
Manual operation:
See
CALCulate<n>:LIMit<k>:ESPectrum:PCLass<Class>:MAXimum
<Level>
This command sets the upper limit level for one power class. The unit is dBm. The limit
always ends at + 200 dBm, i.e. the upper limit of the last power class can not be set. If
more than one power class is in use, the upper limit must equal the lower limit of the
next power class.
Suffix:
<n>
.
irrelevant
<k>
irrelevant
<Class>
1...4
the power class to be evaluated
Parameters:
<Level>
<numeric value>
*RST:
+200
Example:
CALC:LIM:ESP:PCL1:MAX -40 dBm
Sets the maximum power value of the first power class to -40
dBm.
Manual operation:
See
CALCulate<n>:LIMit<k>:ESPectrum:PCLass<Class>:MINimum
<Level>
This command sets the minimum lower level limit for one power class. The unit is dBm.
The limit always start at – 200 dBm, i.e. the first lower limit can not be set. If more than
one power class is in use, the lower limit must equal the upper limit of the previous
power class.
Suffix:
<n>
.
irrelevant
<k>
irrelevant
Remote Commands in Spectrum Analyzer Mode