Interfaces and Connectors
R&S
®
DVMS1
16
Getting Started 2113.7619.02 ─ 12
3.2.3
1 PPS REF IN
This BNC jack is used as input for the 1PPS (1 pulse per second) reference pulse. The
1PPS reference pulse input of the R&S
DVMS is used for measuring the network delay
in DVB
‑
T distribution networks. Use a signal derived from an external GPS receiver
that provides short pulses at exactly 1
second distance. This input is activated, if one of
the SFN synchronization monitoring subparameters "SFN Sync Network Delay" is acti-
vated.
For details, refer to the user manual or help system.
3.2.4
DVI-D
The DVI
‑
D socket provides the monitor output signal of the built-in computer. Use a
computer monitor that provides a resolution of 1024x768 pixels or higher.
You can use a DVI
‑
I cable for connecting R&S
DVMS and display, but the analog video
interface (pins C1 to C4) is not provided by the R&S
DVMS.
Table 3-1: Pin assignment
Pin
Signal
Pin
Signal
1
TMDS data 2-
15
Ground (for +5V)
2
TMDS data 2+
16
Hot plug detect (HPD)
3
TMDS data 2 shield
17
TMDS data 0-
4
Not used
18
TMDS data 0+
5
Not used
19
TMDS data 0 shield
6
DDC clock
20
Not used
Rear Panel