![R&S CMW-KM5 Series User Manual Download Page 810](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802810.webp)
LTE PRACH Measurement
R&S
®
CMW-KM5xx/-KS5xx
810
User Manual 1173.9628.02 ─ 16
chapter 4.5.3.9, "Detected Signal Configuration"
FETCh:LTE:MEAS<i>:PRACh:MODulation:PREamble<Number>?
READ:LTE:MEAS<i>:PRACh:MODulation:PREamble<Number>?
Return the single value results of the "EVM vs Preamble" and "Power vs Preamble"
views, for a selected preamble.
See also
chapter 4.2.9.3, "Detailed Views: EVM vs Preamble, Power vs Preamble"
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Suffix:
<Number>
.
1..16
Number of the preamble for which the results shall be queried
Return values:
<1_Reliability>
<2_PreambleRel>
Reliability indicator for the preamble. The meaning of the
returned values is the same as for the common reliability indica-
tor, see previous parameter.
<3_EVM_RMSlow>
<4_EVM_RMShigh>
<5_EVMpeakLow>
<6_EVMpeakHigh>
Error vector magnitude RMS and peak values for low and high
EVM window position
Range:
0 % to 100 %
Default unit: %
<7_MErr_RMSlow>
<8_MErr_RMShigh>
Magnitude error RMS value for low and high EVM window posi-
tion
Range:
0 % to 100 %
Default unit: %
<9_MErrPeakLow>
<10_MErrPeakHigh>
Magnitude error peak value for low and high EVM window posi-
tion
Range:
-100 % to 100 %
Default unit: %
<11_PErr_RMSlow>
<12_PErr_RMSh>
Phase error RMS value for low and high EVM window position
Range:
0 deg to 180 deg
Default unit: deg
<13_PErrPeakLow>
<14_PErrPeakHigh>
Phase error peak value for low and high EVM window position
Range:
-180 deg to 180 deg
Default unit: deg
<15_FreqError>
Carrier frequency error
Range:
-80000 Hz to 80000 Hz
Default unit: Hz