
LTE PRACH Measurement
R&S
®
CMW-KM5xx/-KS5xx
796
User Manual 1173.9628.02 ─ 16
Parameters:
<Slope>
REDGe | FEDGe
REDGe:
Rising edge
FEDGe:
Falling edge
*RST:
REDG
Example:
See
Configuring the Trigger System
Firmware/Software:
V2.0.10
Manual operation:
See
TRIGger:LTE:MEAS<i>:PRACh:THReshold
<TrigThreshold>
Defines the trigger threshold for power trigger sources.
Parameters:
<TrigThreshold>
Range:
-50 dB to 0 dB
*RST:
-20 dB
Default unit: dB
Example:
See
Configuring the Trigger System
Firmware/Software:
V2.0.10
Manual operation:
See
TRIGger:LTE:MEAS<i>:PRACh:TOUT
<TriggerTimeOut>
Selects the maximum time that the R&S
CMW will wait for a trigger event before it
stops the measurement in remote control mode or indicates a trigger timeout in manual
operation mode. This setting has no influence on "Free Run" measurements.
Parameters:
<TriggerTimeOut>
Range:
0.01 s to 167772.15 s
*RST:
0.1 s
Default unit: s
Example:
See
Configuring the Trigger System
Firmware/Software:
V2.0.10
Manual operation:
See
TRIGger:LTE:MEAS<i>:PRACh:MGAP
<MinTrigGap>
Sets a minimum time during which the IF signal must be below the trigger threshold
before the trigger is armed so that an IF power trigger event can be generated.
Parameters:
<MinTrigGap>
Range:
0 s to 1E-3 s
*RST:
50E-6 s
Default unit: s
Command Reference
深圳德标仪器
135-1095-0799