![R&S CMW-KM5 Series User Manual Download Page 665](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802665.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
665
User Manual 1173.9628.02 ─ 16
FETCh:LTE:MEAS<i>:MEValuation:TRACe:ACLR:CURRent?
FETCh:LTE:MEAS<i>:MEValuation:TRACe:ACLR:AVERage?
READ:LTE:MEAS<i>:MEValuation:TRACe:ACLR:CURRent?
READ:LTE:MEAS<i>:MEValuation:TRACe:ACLR:AVERage?
Returns the absolute powers as displayed in the ACLR diagram. The current and aver-
age values can be retrieved. See also
chapter 3.2.6.6, "Detailed Views: Spectrum
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliability>
<2_UTRA2neg>
<3_UTRA1neg>
Power in the second and first adjacent UTRA channels with
lower frequency
Range:
-100 dBm to 55 dBm
Default unit: dBm
<4_EUTRAneg>
Power in the first adjacent E-UTRA channel with lower fre-
quency
Range:
-100 dBm to 55 dBm
Default unit: dBm
<5_EUTRA>
Power in the allocated E-UTRA channel
Range:
-100 dBm to 55 dBm
Default unit: dBm
<6_EUTRApos>
Power in the first adjacent E-UTRA channel with higher fre-
quency
Range:
-100 dBm to 55 dBm
Default unit: dBm
<7_UTRA1pos>
<8_UTRA2pos>
Power in the first and second adjacent UTRA channels with
higher frequency
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.10.1
FETCh:LTE:MEAS<i>:MEValuation:ACLR:CURRent?
FETCh:LTE:MEAS<i>:MEValuation:ACLR:AVERage?
READ:LTE:MEAS<i>:MEValuation:ACLR:CURRent?
READ:LTE:MEAS<i>:MEValuation:ACLR:AVERage?
CALCulate:LTE:MEAS<i>:MEValuation:ACLR:CURRent?
CALCulate:LTE:MEAS<i>:MEValuation:ACLR:AVERage?
Returns the relative ACLR values as displayed in the table below the ACLR diagram.
The current and average values can be retrieved.
Command Reference
深圳德标仪器