<4_BLER>
Block error ratio (percentage of sent scheduled subframes for
which no ACK has been received)
Range:
0 % to 100 %
Default unit: %
<5_ThroughputAver> Average DL throughput (as percentage of maximum reachable
throughput)
Range:
0 % to 100 %
Default unit: %
<6_DTX>
Percentage of sent scheduled subframes for which neither ACK
nor NACK has been received
Range:
0 % to 100 %
Default unit: %
Example:
See
Performing a Continuous BLER Measurement
Usage:
Query only
Firmware/Software:
V3.2.50
FETCh:INTermediate:LTE:SIGN<i>:EBLer[:PCC]:STReam<Stream>:ABSolute?
FETCh:INTermediate:LTE:SIGN<i>:EBLer:SCC:STReam<Stream>:ABSolute?
FETCh:LTE:SIGN<i>:EBLer[:PCC]:STReam<Stream>:ABSolute?
FETCh:LTE:SIGN<i>:EBLer:SCC:STReam<Stream>:ABSolute?
Return the absolute results of the BLER measurement for one PCC or SCC downlink
stream. These commands are only relevant for transmission schemes with several
downlink streams per carrier.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Suffix:
<Stream>
.
1..2
Selects the downlink stream.
Return values:
<1_Reliability>
<2_ACK>
Number of received acknowledgments
Range:
0 to 2E+9
<3_NACK>
Number of received negative acknowledgments
Range:
0 to 2E+9
<4_Subframes>
Number of already processed subframes
Range:
0 to 2E+9
<5_Throughput>
Average DL throughput
Range:
0 kbit/s to 100E+3 kbit/s
Default unit: kbit/s