![R&S CMW-KM5 Series User Manual Download Page 406](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802406.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
406
User Manual 1173.9628.02 ─ 16
Firmware/Software:
V3.0.50
V3.2.50: added SCC command
Options:
R&S CMW-KS520 for TWO
R&S CMW-KS520 and R&S CMW-KS521 for FOUR
R&S CMW-KS502/-KS552 (FDD/TDD) for SCC
Manual operation:
See
SENSe:LTE:SIGN<i>:CONNection[:PCC]:TSCHeme?
SENSe:LTE:SIGN<i>:CONNection:SCC:TSCHeme?
Queries the transmission scheme for PCC or SCC.
Return values:
<Scheme>
SISO | SIMO | TXDiversity | OLSMultiplex | CLSMultiplex |
CLSingle | SBF5 | SBF8 | DBF78
SISO
: single input single output
SIMO
: single input multiple output (receive diversity)
TXDiversity
: transmit diversity
OLSMultiplex
: open loop spatial multiplexing
CLSMultiplex
: closed loop spatial multiplexing
CLSingle
: closed loop spatial multiplexing, single layer
SBF5
: single-layer beamforming (port 5)
SBF8
: single-layer beamforming (port 8)
DBF78
: dual-layer beamforming (port 7,8)
Example:
See
Configuring General Connection Settings
Usage:
Query only
Firmware/Software:
V3.2.70
Options:
R&S CMW-KS502/-KS552 (FDD/TDD) for SCC
Manual operation:
See
CONFigure:LTE:SIGN<i>:CONNection[:PCC]:PMATrix
<Mode>
CONFigure:LTE:SIGN<i>:CONNection:SCC:PMATrix
<Mode>
Selects the precoding matrix for closed loop spatial multiplexing, for PCC or SCC.
The value must be compatible to the active scenario and transmission mode, see
.
Parameters:
<Mode>
PMI0 | PMI1 | PMI2 | PMI3 | PMI4 | PMI5 | PMI6 | PMI7 | PMI8 |
PMI9 | PMI10 | PMI11 | PMI12 | PMI13 | PMI14 | PMI15
Matrix according to PMI 0, PMI 1, ... PMI15.
*RST:
PMI0
Example:
See
Configuring General Connection Settings
Command Reference
深圳德标仪器