![R&S CMW-KM5 Series User Manual Download Page 112](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802112.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
112
User Manual 1173.9628.02 ─ 16
# RB ... TBSI /TBS
"# RB" selects the number of allocated resource blocks.
"Start RB" specifies the number of the first allocated resource block. This parameter
allows you to shift the allocated RBs within the cell bandwidth.
"Mod" selects the modulation type. The setting influences the allowed transport block
size indices.
"TBSI" selects the transport block size index. "TBS" displays the resulting transport
block size in bits.
Remote command:
Code Rate
Effective channel code rate, i.e. the number of information bits (including CRC bits)
divided by the number of physical channel bits on PDSCH/PUSCH.
Remote command:
Throughput
Expected maximum throughput in Mbit/s (averaged over one frame).
Remote command:
2.4.2 Signaling Control
The individual connection states are controlled via the ON | OFF key, via hotkeys and
via the UE.
The available hotkeys depend on the current connection state. All possible hotkeys are
described in the following.
For background information, refer to
chapter 2.2.8, "Connection States"
ON | OFF (key) / LTE Signaling (softkey)
The ON | OFF key is used to turn the DL signal transmission on or off. The current
state is shown by the softkey. The signal transmission can be switched off any time,
independent of the current connection state. A yellow hour glass symbol indicates that
the signaling generator is currently turned on or off.
GUI Reference
深圳德标仪器
135-1095-0799