CDMA2000 Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
826
User Manual 1173.9511.02 ─ 11
<CTOSigCHState0>,...INVisible | ACTive | IACTive | ALIased
The number of results differs for I and Q signal:
I-Signal
: 3 results (R-PICH, D-DCCH, R-SCH1)
Q-Signal
: 4 results (R-FCH, R-SCH0, R-EACH, R-CCCH)
INV
: No channel available
ACTive
: Active channel
IACtive
: Inactive channel
ALIased
: Aliased channel
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.0.10
5.5.4.16
Spectrum (Traces)
The following commands return the results of the spectrum multi evaluation measure-
ment.
CALCulate:CDMA:MEAS<i>:MEValuation:TRACe:SPECtrum:CURRent?
FETCh:CDMA:MEAS<i>:MEValuation:TRACe:SPECtrum:CURRent?
READ:CDMA:MEAS<i>:MEValuation:TRACe:SPECtrum:CURRent?
Returns the power spectrum traces across the frequency span (8 MHz).
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<CurrSpectrum0>, ...
,<CurrSpectrum1666>
Frequency-dependent power values.
Each of the traces contains 1667 values.
Range:
-100 dB to +57 dB
Default unit: dB
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.20
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
5.5.4.17
ACP Results (Traces)
The following commands return the Adjacent Channel Power (ACP) trace results of the
multi evaluation measurement.
CALCulate:CDMA:MEAS<i>:MEValuation:TRACe:ACP:CURRent:ABSolute?
CALCulate:CDMA:MEAS<i>:MEValuation:TRACe:ACP:AVERage:ABSolute?
CALCulate:CDMA:MEAS<i>:MEValuation:TRACe:ACP:MAXimum:ABSolute?
FETCh:CDMA:MEAS<i>:MEValuation:TRACe:ACP:CURRent:ABSolute?
............................827