1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
408
User Manual 1173.9511.02 ─ 11
Return values:
<1_Reliabiltiy>
Conventions and General Information
. In list mode, a zero relia-
bility indicator indicates that the results in all measured seg-
ments are valid. A non-zero value indicates that an error occur-
red in at least one of the measured segments.
{<2_SegReliability>
0 | 3 | 4 | 8
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_RRI>, <4_Pilot>,
<5_ACKDSC>,
<6_AuxPilot>,
<7_DRC>, <8_Data>}
INVisible | ACTive | IACTive
INV
: No channel available
ACTive
: Active channel
IACtive
: Inactive channel
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.20
Options:
R&S CMW-KM012
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:MINimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:ACP:SDEViation?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:ACP:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:ACP:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:ACP:MINimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:ACP:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:ACP:SDEViation?
Returns all ACP value results in list mode. To define the statistical length for
AVERage
,
MAXimum
,
MINimum
calculation and enable the calculation of the results use the com-
mand
.
The ranges indicated below apply to all results except standard deviation results. The
minimum for standard deviation results equals 0. The maximum equals the width of the
indicated range divided by two. Exceptions are explicitly stated.
The values listed below in curly brackets {} are returned for each active segment:
{...}
seg 1
, {...}
seg 2
, ..., {...}
seg n
. The number of active segments n is determined by
.
Command Reference