CONFigure:WCDMa:SIGN:CELL:CPC:HORDer:SEND
CONFigure:WCDMa:SIGN:CELL:CPC:HORDer:SEND?
2.5.1.10
Configuring UE Measurement Report Settings
// *****************************************************************************
// Enable UE measurement report, set interval between two report messages,
// and enable the evaluation of all information elements for current cell,
// carier 2, and WCDMA, GSM, and LTE neighbor cells.
// *****************************************************************************
CONFigure:WCDMa:SIGN:UEReport:ENABle ON
CONFigure:WCDMa:SIGN:UEReport:RINTerval 5
CONFigure:WCDMa:SIGN:UEReport:CCELl:ENABle ON,ON,ON,ON,ON,ON
CONFigure:WCDMa:SIGN:UEReport:NCELl:ENABle ON,ON,ON,ON,ON
CONFigure:WCDMa:SIGN:UEReport:NCELl:WCDMa:ENABle ON, ON, ON, ON, ON
CONFigure:WCDMa:SIGN:UEReport:NCELl:GSM:ENABle ON, ON
CONFigure:WCDMa:SIGN:UEReport:NCELl:LTE:ENABle ON, ON
2.5.1.11
Configuring Message Monitoring
// *****************************************************************************
// Enable message monitoring for WCDMA. Select address number 2 from the global
// logging PC address pool. Query the corresponding IP address string.
// *****************************************************************************
CONFigure:WCDMa:SIGN:MMONitor:ENABle ON
CONFigure:WCDMa:SIGN:MMONitor:IPADdress IP2
CONFigure:WCDMa:SIGN:MMONitor:IPADdress?
2.5.1.12
Switching on the Cell Signal and the UE (Signaling)
// *****************************************************************************
// Connect the UE (switched off). Switch on the DL signal. Query the cell
// state until it equals ON,ADJ (DL signal available at RF connector).
// *****************************************************************************
WAITKEY >Ensure that the UE is connected to the instrument and switched off<
SOURce:WCDMa:SIGN:CELL:STATe ON
WHILE SOURce:WCDMa:SIGN:CELL:STATe:ALL? <> "ON,ADJ"
// *****************************************************************************
// Ensure that the reduced signaling mode is disabled.
// *****************************************************************************
CONFigure:WCDMa:SIGN:CELL:RSIGnaling OFF
// *****************************************************************************
// Switch on the UE and wait until it is registered and attached.
// *****************************************************************************
WAITKEY >Switch on the UE<