R&S 1421.3509.02 Getting Started Download Page 1

R&S

®

NRQ6

Frequency Selective

Power Sensor

Getting Started

 

1178370502
Version 10

(;ÜU52)

Summary of Contents for 1421.3509.02

Page 1: ...R S NRQ6 Frequency Selective Power Sensor Getting Started 1178370502 Version 10 U52...

Page 2: ...warz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG All other trademarks are the properties...

Page 3: ...1 5 Tutorials 12 2 1 6 Instrument security procedures 12 2 1 7 Basic safety instructions 12 2 1 8 Data sheets and brochures 12 2 1 9 Release notes and open source acknowledgment OSA 13 2 1 10 Applica...

Page 4: ...O REF 35 4 7 Clock I O CLK 35 4 8 Local oscillator I O LO 36 4 9 Fan openings 36 5 Operating concepts 37 5 1 R S NRP Toolkit 37 5 1 1 Versions and downloads 37 5 1 2 System requirements 38 5 1 3 R S...

Page 5: ...Contents R S NRQ6 5 Getting Started 1178 3705 02 10 6 2 Ethernet interface 51 6 2 1 VISA resource strings 51 7 Contacting customer support 55 Index 57...

Page 6: ...Contents R S NRQ6 6 Getting Started 1178 3705 02 10...

Page 7: ...ios MSR fast power servoing and calibration of multiple active antenna modules for beamforming Where do I find safety information Safety information is part of the product documentation It warns you o...

Page 8: ...affect safety and are not permitted Never open the casing of the product Only service personnel authorized by Rohde Schwarz are allowed to repair the product If any part of the product is damaged or b...

Page 9: ...its service life For more information see the user manual 1 3 Warning messages in the documentation A warning message points out a risk or danger that you need to be aware of The signal word indicates...

Page 10: ...Safety and regulatory information R S NRQ6 10 Getting Started 1178 3705 02 10 Warning messages in the documentation...

Page 11: ...1 1 Getting started manual Introduces the R S NRQ6 and describes how to set up and start working with the product A printed version is delivered with the R S NRQ6 2 1 2 User manual Contains the descr...

Page 12: ...utorials offer guided examples and demonstrations on operating the R S NRQ6 They are provided on the product page of the internet 2 1 6 Instrument security procedures Deals with security issues when w...

Page 13: ...ohde schwarz com application NRQ6 2 2 Key features The R S NRQ6 frequency selective power sensor sets standards in RF perfor mance and usability Outstanding key features are Combines the advantages of...

Page 14: ...Welcome R S NRQ6 14 Getting Started 1178 3705 02 10 Key features...

Page 15: ...er 3 Using the delivery notes check the equipment for completeness 4 Check the equipment for damage If the delivery is incomplete or equipment is damaged contact Rohde Schwarz 3 2 Choosing the operati...

Page 16: ...ble shielded RF and inter face cables Always terminate open cable ends Ensure that connected external devices comply with EMC regulations Signal input and output levels Information on signal levels is...

Page 17: ...RF output of your DUT Take care not to tilt it SMART SENSOR TECHNOLOGY NRQ6 Frequency Selective Power Sensor LAN PoE Host Interface Sample Clock I O Default 120 MHz LO I 0 180 4 NOTICE Risk of damagin...

Page 18: ...a LAN PoE interface 1 Use a suitable cable as described in Chapter 4 3 LAN PoE interface on page 32 2 Connect one end of the cable to the LAN interface of the R S NRQ6 3 Connect the other end of the c...

Page 19: ...ce Further information Chapter 3 5 Connecting to a power supply on page 18 Chapter 6 Remote control interfaces and protocols on page 49 Contents Setup with a PoE ethernet switch 19 Setup with a PoE in...

Page 20: ...livery 3 Connect the computer to the Ethernet switch 4 Establish a connection between the R S NRQ6 and the network See Chap ter 3 6 1 4 Establishing a connection on page 22 3 6 1 2 Setup with a PoE in...

Page 21: ...R S NRQ6 and the network See Chap ter 3 6 1 4 Establishing a connection on page 22 3 6 1 3 Setup with a PoE injector NRQ6 Frequency Selective Power Sensor LAN PoE Host Interface Sample Clock I O Defau...

Page 22: ...er By default the R S NRQ6 is configured to use dynamic TCP IP configuration DHCP and to obtain the address information automatically If both LAN status LEDs are illuminated in green color the R S NRQ...

Page 23: ...rks including peer to peer networks The R S NRQ6 supports zero configuration networking used in networks without DHCP server such as peer to peer networks Thus you can connect the R S NRQ6 to a networ...

Page 24: ...ription on how to set the IP address manually refer to the user manual Identify the R S NRQ6 using hostnames In networks using a DHCP server it is recommended that you address the R S NRQ6 by its uniq...

Page 25: ...S NRP Toolkit 7 PoE injector 8 AC supply 1 Connect the R S NRQ6 to the signal source DUT See Chapter 3 4 Con necting to a DUT on page 17 2 Connect the R S NRQ6 to the power supply See Chapter 3 5 Con...

Page 26: ...B host If the computer has a USB C port use an R S NRP ZKC cable instead of an R S NRP ZKU cable If you want to disconnect the cable from the host interface a Loosen the union nut of the screw lock ca...

Page 27: ...omputer with USB host interface 4 Optional Connect to trigger source 5 Optional Connect to triggered device 6 R S NRP Z5 sensor hub 7 Signal source DUT 8 R S NRQ6 9 R S NRP ZK6 cable 10 PoE injector 1...

Page 28: ...S NRX using the host interface The R S NRX supports the configura tion of 2 directly connected R S NRQ6 if enhanced accordingly For details see the user manual and the data sheet of the R S NRX The R...

Page 29: ...r into the host interface of the R S NRQ6 b Tighten the union nut manually 2 8 pin male connector of R S NRP ZK8 cable a Insert this connector into one of the sensor ports of the R S NRX If you want t...

Page 30: ...Preparing for use R S NRQ6 30 Getting Started 1178 3705 02 10 Connecting to a controlling host...

Page 31: ...penings on page 36 3 Status display see Chapter 4 2 Status information on page 32 4 LAN interface see Chapter 4 3 LAN PoE interface on page 32 5 Host interface see Chapter 4 4 Host interface on page 3...

Page 32: ...LED shows the state of the R S NRQ6 by color and blinking fre quency Table 4 1 Possible states Color Illumination State White Steady Idle The sensor performs no measurement and is ready for use White...

Page 33: ...the R S NRQ6 to a local area network LAN for remote control remote operation and data transfer R S NRQ6 requires PoE The electrical power for the R S NRQ6 is provided by PoE power over Ethernet The I...

Page 34: ...sensor is powered over PoE You can operate it using the Ethernet inter face No light No PoE power is present LAN reset button See 3 in Figure 4 2 Resets the Ethernet connection parameters of the powe...

Page 35: ...eference clock By default the R S NRQ6 generates a 10 MHz reference signal and uses it as reference clock You can use this signal as a reference clock for other devices output Also you can supply an e...

Page 36: ...4 8 Local oscillator I O LO See 8 in Figure 4 1 The female SMA connector is used as an input or output for the local oscillator LO signal For input and output specifications read the label on the R S...

Page 37: ...nd to install the R S NRP Toolkit The R S NRP Toolkit is the basic software package that supplies low level driv ers and tools for all power sensors The components of the R S NRP Toolkit depend on the...

Page 38: ...e R S NRP Toolkit installer for Windows based systems contains the compo nents described in the release notes available at www rohde schwarz com soft ware nrp toolkit To install the R S NRP Toolkit 1...

Page 39: ...ou can use the Firmware Update for NRP Family program to load new firmware for the power sensors For further details refer to the user manual 5 2 Browser based user interface With the integrated brows...

Page 40: ...T as described in Chapter 3 4 Connecting to a DUT on page 17 To display the Web user interface 1 Open a supported web browser 2 Enter the hostname of the R S NRQ6 you want to connect to See Chap ter 3...

Page 41: ...Sensor information 5 Top pane 6 Settings pane 7 Result pane Sensor name or hostname 1 in Figure 5 1 If you do not specify a sensor name the hostname is displayed For details see the user manual Status...

Page 42: ...ure 5 1 Displays the settings you have selected in the navigation pane Result pane 7 in Figure 5 1 Displays the result for the selected measurement mode 5 2 2 Tooltips The web user interface provides...

Page 43: ...djusts the y axis of the chart constantly to the signal To go back to an optimized setting of the y axis click Resets the axes 5 2 4 Setting parameters If a parameter is not grayed you can change its...

Page 44: ...mber you can also Use the spinner One click changes the number by one increment If you keep the arrow pressed you can quickly scroll through the possible val ues Use the right or left arrow key of you...

Page 45: ...the power sensor to the signal source See Chapter 3 4 Connecting to a DUT on page 17 Starting a measurement For a detailed description of how to measure in this setup refer to the user man ual of the...

Page 46: ...NRQ6 easily The change to remote control occurs on the fly Switching to remote control 1 Establish a link between the controller and the R S NRQ6 2 Send a SCPI command to the R S NRQ6 The R S NRQ6 cha...

Page 47: ...e R S NRQ6 changes into local mode The lock of the web user interface is removed Further information See the user manual for details Chapter 6 Remote control interfaces and protocols on page 49 Chapte...

Page 48: ...Operating concepts R S NRQ6 48 Getting Started 1178 3705 02 10 Remote control...

Page 49: ...SA Socket communication LAN Ethernet TCPIP host address LAN device name port SOCKET VISA is a standardized software interface library providing input and output func tions to communicate with instrume...

Page 50: ...ement class Using a VISA library such devices support service request trigger and other operations that are commonly found in GPIB devices USB resource string The VISA resource string for USBTMC devic...

Page 51: ...network See Chapter 3 6 1 Computer using a LAN connection on page 19 2 Make sure that the R S NRQ6 is powered by PoE For details see R S NRQ6 requires PoE on page 33 6 2 1 VISA resource strings The V...

Page 52: ...italics HiSLIP TCPIP IP address or hostname hislip0 INSTR hislip0 is the HiSLIP device name designates that the interface protocol HiSLIP is used mandatory hislip0 is composed of HiSLIP device name Hi...

Page 53: ...20 the valid resource string using VXI 11 protocol is TCPIP 10 111 11 20 INSTR The DNS host name is nrq6 100001 the valid resource string is TCPIP nrq6 100001 hislip0 HiSLIP TCPIP nrq6 100001 inst0 V...

Page 54: ...Remote control interfaces and protocols R S NRQ6 54 Getting Started 1178 3705 02 10 Ethernet interface...

Page 55: ...ct contact our customer support center A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation program ming or applicat...

Page 56: ...Contacting customer support R S NRQ6 56 Getting Started 1178 3705 02 10...

Page 57: ...ocal oscillator 36 Reference clock 35 RF 31 Sampling clock 35 Trigger 35 Controlling host Computer using LAN 19 Computer using USB 24 R S NRX 28 Customer support 55 D Data sheets 12 Disconnecting R S...

Page 58: ...Connecting 18 Preparing for use 15 R R S NRP Toolkit 37 Components for Windows based sys tems 38 Firmware update 39 Installation under Windows 38 System requirements 38 Versions 37 R S NRP Z5 26 R S N...

Page 59: ...B sensor hub 26 USB interface Remote control 49 USB resource string 50 USB sensor hub 26 USBTMC protocol 50 User manual 11 V VISA 51 VXI 11 52 W Warning message 9 Web user interface 39 Chart toolbar 4...