Command reference
R&S
®
ZNA
1388
User Manual 1178.6462.02 ─ 20
Suffix:
<Ch>
.
Channel number
<Seg>
Sweep segment number
<PortId>
Port number
Parameters:
<Boolean>
OFF (0)
No port-specific power level for port <PortId> in segment <Seg>
of channel <Ch>.
If
[SENSe<Ch>:]SEGMent<Seg>:POWer[:LEVel]:CONTrol
is set to ON, the segment power level
LEVel][:IMMediate][:AMPLitude]
ON (1)
The port-specific power level
segment <Seg> of channel <Ch>.
*RST:
OFF
Manual operation:
See
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol
<ReceiverName>, <Mode>
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol?
<ReceiverName>
Defines port- and segment-specific IF gain settings.
These settings apply if and only if segmented gain control (GC) is enabled (see
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol:CONTrol
).
Note:
●
This applies to the wideband signal path only.
●
instead, if
no distinction between different sweep segments shall be made.
Suffix:
<Ch>
.
Channel number
<Seg>
Sweep segment number
Setting parameters:
<Mode>
LDIStortion | LNOise
LDIStortion
0 dB gain, for high input levels
LNOise
10 dB gain, for low input levels
*RST:
LDIStortion
SCPI command reference