Command reference
R&S
®
ZNA
1295
User Manual 1178.6462.02 ─ 20
Usage:
Setting only
Manual operation:
See
[SENSe<Ch>:]CORRection:COLLect:FIXTure:EXPort
<FixtureFile>,
<StandardType>, <TestPort1>[, <TestPort2>]...
[SENSe<Ch>:]CORRection:COLLect:FIXTure:IMPort
<FixtureFile>,
<StandardType>, <TestPort1>[, <TestPort2>...]
Loads/saves "Direct Compensation" data from/to the specified file.
The
EXPort
command first acquires the required data, just as a
]CORRection:COLLect:FIXTure[:ACQuire]
would do.
"Direct Compensation" data files are standard
, containing reflection parame-
ter traces for the related port(s) and standard.
Table 7-16: Direct Compensation data
#TestPorts
File Type
1
s1p
>=1
csv
For 1-port Touchstone files (*.s1p) only a single test port can be specified - otherwise
an error is raised.
Suffix:
<Ch>
.
Channel number
Parameters:
<FixtureFile>
Path to the "Direct Compensation" data file, either absolute or
relative to the current directory (set/queried using
Setting parameters:
<StandardType>
OPEN | SHORt
Terminating standard type
<TestPort1>[,
<TestPort2>, ...]
Test port numbers. For a fixture compensation, n different (but
not necessarily consecutive) port numbers must be specified.
SCPI command reference