Command reference
R&S
®
ZNA
1070
User Manual 1178.6462.02 ─ 20
Parameters:
<Inductance>
Inductance L<Cmp> for the specified circuit model.
Range:
-1H to 1 H.
Increment: 1 pH (1E-12 H)
*RST:
1 nH (1E-9 H)
Default unit: H
Parameters for setting and query:
<CircuitModel>
STSL | SLST | CSSL | LSSC | LSSL | SLCS | SCLS | SLLS |
GSSL | LSSG | SLGS | SGLS
Possible circuit models (character data); see
Example:
*RST; :SOUR:LPOR1 1,2; :CALC:TRAN:VNET:BAL:
DEEM:PAR:L1? CSSL
Create a balanced port and query the default inductance L1 for
the Serial Cs, shunt L circuit model. The response is 1E-009 (1
nH).
CALC:TRAN:VNET:BAL:DEEM:PAR:L1 CSSL, 2.2E-9
Increase the inductance to 2.2 nH.
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:BALanced:DEEMbedding<LogPt>:
PARameters:R<Cmp>
<CiruitModel>, <Resistance>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:DEEMbedding<LogPt>:
PARameters:R<Cmp>?
<CiruitModel>
Specifies the resistance value R<Cmp> in the different circuit models for balanced port
deembedding.
In the query form, the <Resistance> parameter must be omitted. The command returns
the resistance value for the specified circuit model.
Suffix:
<Ch>
.
Channel number
<LogPt>
Logical port number (balanced port)
<Cmp>
Number of resistance in circuit model. The total number of resis-
tances depends on the selected circuit model.
Parameters:
<Resistance>
Resistance R<Cmp> for the specified circuit model.
Range:
-10 MΩ to 10 MΩ.
Increment: 1 mΩ (1E-3 Ω)
*RST:
0 Ω for all resistances connected in series with an
inductance. 10 MΩ for all resistances connected in
parallel with a capacitance
Default unit: Ω
SCPI command reference