Command reference
R&S
®
ZNA
1025
User Manual 1178.6462.02 ─ 20
<Type>
–
Boolean identifier for the ripple limit range type. 1 for
ripple limit range on (with limit check). 0 for ripple limit range off:
The range is defined, but no limit check result displayed. The
result is still available via
<StartStimulus>/<StopStimulus>
–
stimulus values (unitless) con-
fining the ripple limit range
<RippleLimit>
–
ripple limit (unitless) in the stimulus range
between <StartStimulus> and <StopStimulus>
The unit of a stimulus value is adjusted to the sweep type of the
active channel (
), the unit of a rip-
ple limit is adjusted to the format of the active trace
(
Range:
Virtually no restriction for ripple limit ranges.
*RST:
n/a (no ripple limit line defined after a reset)
Example:
*RST; CALC:RIPP:DATA 1, 1500000000, 2000000000,
3, 1, 2000000000, 3000000000, 5
Define and enable a ripple limit range in the stimulus range
between 1.5 GHz and 2 GHz, assigning a ripple limit of +3 dB.
Define and enable a second ripple limit range in the stimulus
range between 2 GHz and 3 GHz, assigning a ripple limit of +5
dB.
CALC:RIPP:DISP ON
Show the ripple limits in the active diagram.
Manual operation:
See
"Add / Insert / Delete / Delete All / Align All"
CALCulate<Chn>:RIPPle:DELete:ALL
Deletes all ripple limit ranges.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Example:
*RST; CALC:RIPP:DATA 1,1500000000, 2000000000,
3, 1, 2000000000, 3000000000, 5
Define and enable a ripple limit range in the stimulus range
between 1.5 GHz and 2 GHz, assigning a ripple limit of +3 dB.
Define and enable a second ripple limit range in the stimulus
range between 2 GHz and 3 GHz, assigning a ripple limit of +5
dB.
CALC:RIPP:DEL:ALL
Delete both created ripple limit ranges.
Usage:
Event
Manual operation:
See
"Add / Insert / Delete / Delete All / Align All"
SCPI command reference