9.2 SCPI-Specific Error Messages
Error code
Error text in the case of queue poll
Error explanation
0
No error
This message is output if the error queue does not contain any entries.
Error code
Error text in the case of queue poll
Error explanation
-100
Command Error
The command is faulty or invalid.
-101
Invalid Character
The command contains an invalid sign.
Example: A header contains an ampersand, "
SENSe&
".
-102
Syntax error
The command is invalid.
Example: The command contains block data the instrument does not accept.
-103
Invalid separator
The command contains an invalid sign instead of a separator.
Example: A semicolon is missing after the command.
-104
Data type error
The command contains an invalid value indication.
Example: ON is indicated instead of a numeric value for frequency setting.
-105
GET not allowed
A Group Execute Trigger (GET) is within a command line.
-108
Parameter not allowed
The command contains too many parameters.
Example: Command
SENSe:FREQuency:CENTer
permits only one frequency
indication.
-109
Missing parameter
The command contains too few parameters.
Example: The command
SENSe:FREQuency:CENTer
requires a frequency
indication.
-110
Command header error
The header of the command is faulty.
-111
Header separator error
The header contains an invalid separator.
Example: the header is not followed by a "White Space", "
*ESE255
"
-112
Program mnemonic too long
The header contains more than 12 characters.
-113
Undefined header
The header is not defined for the instrument.
Example:
*XYZ
is undefined for every instrument.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...