EXCLUDE LO
The
EXCLUDE LO
softkey limits the frequency range for the marker search func-
tions or disables the limit.
Remote command:
CALC:MARK:LOEX ON
PEAK
EXCURSION
The
PEAK EXCURSION
softkey enables – for level measurements – the entry of a
minimum level value by which a signal must rise or fall so that it will be identified as
a maximum or a minimum by the
NEXT PEAK
and
NEXT MIN
search functions.
Valid entries are from 0 dB to 80 dB; the resolution is 0.1 dB.
Remote command:
CALC:MARK:PEXC 10dB
The default setting for the peak excursion is 6 dB. This value is sufficient for the
NEXT PEAK
and
NEXT MIN
functions since, in this mode, the next lower maximum
or next higher minimum will always be detected.
If
NEXT PEAK LEFT
or
NEXT PEAK RIGHT
is selected, these functions search for
the next relative maximum left or right of the current marker position irrespective of
the current signal amplitude.
Relative maximum
is understood to mean a decrease
of the signal amplitude by a defined value – i.e. the peak excursion – right and left of
the amplitude peak.
The 6 dB level change set as a default value may be attained already by the inher-
ent noise of the instrument. In such a case, the R&S ESU would identify noise peaks
as maxima or minima. The value entered for the
PEAK
EXCURSION
should there-
fore be higher than the difference between the highest and the lowest value mea-
sured for the displayed inherent noise.
The following example illustrates the effect of different settings of the
PEAK
EXCURSION
.
activated
Because of the feed through of the first local oscillator to the first
intermediate frequency at the input mixer, the LO is represented as a
signal at 0 Hz. To avoid the marker jumping to the LO at 0 Hz with the
peak function when setting the display range, this frequency is
excluded. The minimum frequency to which the marker jumps, is
≥
6
× resolution bandwidth (RBW).
deactivated
No restriction to the search range. The frequency 0 Hz is included in
the marker search functions.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...