CONTROLS & CONNECTIONS
OPERATING MODES & DISPLAYS
USER SELECTIONS
SD Card
Slot
ON/OFF
Blood Pressure Measurement & Related Commands
SpO2 & Related Commands
OR MODE
BP cycle set
CLINIC MODE
DIRECTIONS FOR USE
(abbreviated*)
1.
Power the
II
:
Press and release the ON/OFF button on the right side of the unit to power
the device on (See CONTROLS & CONNECTIONS section above).
2.
Place the sensors.
a.
BP cuff.
Select the proper size cuff based on measurement site, animal’s
size and cuff index markings. Apply the cuff snuggly. If necessary, attach
the cuff to the proper extension, provided.
b.
SpO2 sensor (if equipped).
Clip the sensor to the tongue or ear and
touch the ON O2sat button to begin measuring.
c.
Temperature (if equipped)
. Insert the temperature probe orally into the
esophagus or rectally. The temperature value will be displayed on the
right side of the screen just under the SpO2 heart rate (See OPERATING
MODES & DISPLAYS section above).
3.
Set Up
II
.
a.
Attach cuff, SpO2 cable and temperature connectors to the top of the
unit (See CONTROLS & CONNECTIONS section above).
b.
Press the Species/Cuff Site button repeatedly to change the different
settings. Stop when you arrive at the appropriate setting (See USER
SELECTIONS section above).
AC/DC Adapter
Connection
Quick Reference Instructions
AC/DC Adapter
4.
Measuring in the O.R.
a.
BP settings in OR Mode.
BP cycle times can be set by touching the BPcycle
button repeatedly until you arrive at the desired time interval. High and low
systolic BP alarms can also be set. To set alarms, repeatedly touch the BP
HiAlarm and LoAlarm buttons until you reach the desired value (See Blood
Pressure Measurement & Related Commands in USER SELECTIONS section
above). Press BP Go/Stop to initiate cycle.
b.
SpO2 settings in OR Mode.
A low alarm for SpO2 can be set by repeatedly
touching the LoAlarm button in the second row of buttons next to the SpO2
value. Audible heart rate can also be set at 1 of 5 different volumes; touch
the HrAudio button until you reach the desired volume (See SpO2 & Related
Commands in the USER SELECTIONS section above).
5.
Measuring in the Exam Room.
For use in the exam room mode, leave the BP cycle setting OFF. For each
reading, touch the BP Go/Stop button. In this mode a trend of readings, along
with the NSV (after at least two readings), will appear on the bottom left of the
screen and a history of the last 10 readings taken will be displayed on the
bottom right of the screen.
*More detailed information is available in the Operator’s Manual. A copy of the manual is available for download at
www.petmap.com
.
To contact Customer Service, call 813-289-5555; toll free 800-231-6370.
SpO2 Connector
Cuff Connector
Temperature
Connector
Mini
USB Port
Charging indicator
green – fully charged
amber - charging
Nominal Session
Value (NSV)
Systolic BP
Diastolic BP
Mean Arterial Pressure
Heart rate (from BP)
SpO2 & pleth
SpO
2
Heart rate
Temperature
Systolic BP
Diastolic BP
Heart rate (from BP)
SpO
2
Heart rate
Measurement History
Temperature
Time of Day
Battery status
Species, Cuff site setting
Cuff
Pressure
BP Trend
Temperature
Trend
Press and release to set the BP measurement frequency which, when set, places the device into OR mode in which BP reading are
automatically repeated at the selected interval. The available BPcycle options are STAT (BP cycles rapidly for three minutes then reverts
automatically to a 2 min cycle time), 1 Min, 2 Min, 3 Min, 4 Min, 5 Min, 10 Min, 15 Min, 20 Min, 25 Min and 30 Min. Once the desired
frequency is selected, the user must press the BP Go/Stop button to begin the measurements. Press and hold the BP cycle button to turn the
cycle mode OFF.
Press and release to set the low limit alarm for systolic pressure. The available settings are 60, 80, 100, 120, 140, 160 and OFF. Press and hold to
turn the alarm OFF.
Press and release to set the high limit alarm for systolic pressure. The available settings are 150, 175, 200, 225, 250 and OFF. Press and hold to
turn the alarm OFF.
Press and release to set the species and cuff site which is displayed at the top. The seven available settings are DOG (ForeArm, HindFoot and
Tail), CAT (ForeArm, HindFoot and Tail) and Optimize…None. The non-optimized mode should be used on any species other than dog or cat or
when comparing petMAP to Doppler or other oscillometric BP devices.
Press and release to initiate a BP reading in Clinic Mode, or to initiate a series of automatically cycled BP readings
in the OR Mode.
Press and release to start the measurement of O2 saturation. When the SpO2 monitor is ON, the button will show ON and the plethysmographic
waveform will be displayed, along with the SpO2 value and heart rate derived from the SpO2 sensor. It may take 10-15 seconds for the display to
stabilize after switching O2 ON.
Press and release to set the low limit alarm for SpO2. The available settings are 96, 94, 92, 90, 88, 86, 84, 82 and OFF. Press and hold to turn
alarm OFF.
Press and release to set the volume for the SpO2 audible heart rate cardiotachometer. The available settings are ON 1 – ON 5 ( 5 being the
loudest) and OFF. Press and hold to turn the audio OFF.
Time of Day
If an SD card is in use, press to capture an image of the screen in a file on the SD card. Similarly, the unit will prompt the user at power off for the
same feature. (See Operator’s Manual)
Developed by:
Manufactured,
Distributed &
Serviced by:
R400261-A
160401
ECG plug in
**
CO2 plug in
**
** ECG and CO2 modules are available for purchase. Instructions for use are provided with each module.