Battery Operation Procedures

Please full charge battery before first use

Using one or two Batteries

• The EX50Li allows the option of using one or two battery packs.  

• When using one battery, simply plug the battery into either one of the two battery 

connectors (left, right or both). 

• Be sure to secure the unused battery connector by placing electrical tape over the 

contacts.  

• When powered on, the system will identify quantity of batteries and locations used.

 

• For a true redundant system, two batteries are recommended.   

• When using dual batteries, it’s important that both batteries be of the same charge 

level and ideally of the same age and condition.

• The control system will control all battery charge and discharge during use.

• Battery status will be displayed on control panel.

• When AC is disconnected and Speed Control is off (speed = 0), the controller and 

battery(s) will enter a sleep mode to conserve the battery power after 60 minutes of no 

activity. 

 

• To wake the ventilator, push and hold WAKE | STOP Button           on Control Panel. 

Battery Status LED Light will show white solid for the status. The unit will return to 

sleep mode if not used within 10 minutes. 

 

• The ventilator starts at the lower speed = 0. Speed will vary by 11 levels - from 11 

(highest) to 0 (off). Turn clockwise to increase speed. At level 11 (the highest), if keep 

turning the control knob clockwise, the speed will not change, it will stay at highest 

speed all the time. To slow down, turn counterclockwise.  

 

• If you want to increase the speed, push and hold the MAX Button               Ventilator 

Status LED Light will flash white for the status. Remember that this will only work when 

2 batteries are connected to the ventilator and when it is operating exclusively on DC 

current source (battery).

 

• To STOP the ventilator, push and hold WAKE|STOP Button            on Control Panel. 

Battery Status LED Light will be unlit. 

 

• Battery(s) may be swapped for charged batteries at any time.  

 

• Reduce run speed to minimum required to increase runtime.

Battery Operation Procedures

Run Time

Run time refers to how long the ventilator on battery power will last under a given load. 

We will assume both batteries have full charge beforehand and also 100% efficiency (Read 

"Factors that affect Battery Life" section):

2 Batteries

Speed Level Knob

At maximum speed

45 minutes

11

At maximum speed and Max 

button activated

30 minutes

Max button activated

Summary of Contents for EL5500

Page 1: ...San Diego Luxembourg Dubai Ningbo Singapore FlowPath Control GEN II Owner s Manual ALL PURPOSE BATTERY VENTILATOR ...

Page 2: ...Interface 6 Adjusting Angle 7 Operational Modes 8 AC Operation 8 DC Operation 8 Connection of Battery Pack 8 9 Battery Operation Procedures 10 Run Time 11 Charging Procedure 12 Battery Status Indicator Lights 13 Battery Pack Protection 13 Storage Transport Modes 14 How to Activate Storage Transport Mode 14 AC Power Cord 15 Operating Limitations 15 Lithium Ion Battery Maintenance Guidelines 16 Over...

Page 3: ... top of controller controls all functions Specifications LB9106 Hot Surface Do Not Touch Heat Sink or Lights Warning Labels Safety Precautions Electrical shock hazard Do not open enclosures DO NOT START with signs of visible damage Blower is not intended for operation in explosive atmospheres Wear ear protection when close by Keep body parts and loose objects away from intake of fan Do not move wh...

Page 4: ...g STORAGE MODE Storage Transport Mode L R BAT FAULT PUSH FOR WAKE STOP PUSH FOR MAX AC PWR DC PWR FAULT NO PWR STORAGE MODE MAX IntellisenseTM E3 LIGHTS SPEED 1 2 3 4 5 6 AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC PWR MAX FAULT NO PWR STORAGE MODE AC PWR DC...

Page 5: ...the warranty 1 Connect the fan to an AC power source 2 Status LED Light will automatically turn green displaying the status Ventilator is connected on AC Power Supply 3 Start the ventilator by using the Speed Control knob to the desired speed Note You can keep the batteries on their location without charging the battery Battery Indicator Lights will turn off because there is no battery charging wh...

Page 6: ... the status The unit will return to sleep mode if not used within 10 minutes The ventilator starts at the lower speed 0 Speed will vary by 11 levels from 11 highest to 0 off Turn clockwise to increase speed At level 11 the highest if keep turning the control knob clockwise the speed will not change it will stay at highest speed all the time To slow down turn counterclockwise If you want to increas...

Page 7: ...to cool down in between charging and discharging L R BAT FAULT PUSH FOR WAKE STOP PUSH FOR MAX AC PWR DC PWR FAULT NO PWR STORAGE MODE MAX IntellisenseTM E3 LIGHTS SPEED Make sure the battery pack is connected correctly to the ventilator as described above in Connection of Battery Pack The next step is to leave the ventilator off During charging the battery indicator lights will flash The battery ...

Page 8: ...Storage Transport Mode can be engaged with either one 1 or two 2 battery packs installed on the fan How to activate Storage Transport Mode AC Power Cord CORD STORAGE This battery fan was designed to replace corded AC fans optimizing cordless operations The AC power cord is designed to be removable for the convenience of those users who choose to operate cordless The AC power connector is a Push Pu...

Page 9: ...used for 6 months check the charge status and either charge or dispose of the battery as appropriate Recommendations Battery packs will last significantly longer when run in pairs two battery packs per fan as there is 50 less discharge current per pack As with any equipment batteries will wear out faster with heavy use Depth of Discharge DoD determines the cycle count of the battery The smaller th...

Page 10: ...ress protection Quickly inspect for obvious damage after every use If damage is noted contact Authorized Service Center for inspection testing and maintenance Damage to gasket may compromise water ingress protection increasing risk of pack failure Do not store in same compartment with combustible or highly flammable material as gasoline and diesel oil Liquid damage is not covered under warranty Ac...

Page 11: ...kg ft m tilt cfm m hr EX50Li 18 46 0 8 22x21x12 56x53x30 EL5500 EL5500 230 45 20 2798 14 4 3 13 9 635 16 370 AC EX50Li 18 46 0 8 22x21x12 56x53x30 EL5500 EL5500 230 45 20 3045 14 4 3 9 10 120 17 194 DC Euramco Group 2746 Via Orange Way Spring Valley CA 91978 USA Ph 1 619 670 9590 www Euramco com Page 1 of 1 DECLARATION OF CONFORMITY BATTERY POWERED FANS Year of Manufacture 2020 Manufacturer Euramc...

Page 12: ...loded View EX50Li Gen II 24 15 16 16 15 26 22 21 14 37 TOWARD TILT PLATE CONCAVE SIDE 22 6 4 2 33 28 29 35 36 32 F 3 17 19 5 57 10X 51 5X 58 30 8X 40 23 5X 12 50 31 8 OF EL6015 63 62 3 OF EL6015 See parts index pg 24 ...

Page 13: ... 250 NYLON WASHER 062 37 FF99432 6 x 1 2 P TRUSS SMS PLTD STL 51 FZ9500461 PT POWER CORD QUICK DISCONNCT Type E F Schuko 57 EL CUS 4762 PIPE PLUG 3 8 NPT MACHINED 58 FH93816 MACH MOTOR CONTROLLER ASSY G2 62 EMC E55010G2 Telescoping Handle Wheel Kit EX50Li Factory Install 63 EL6015 Plug Types The EX50Li is suitable for worldwide applications Both a voltage frequency converter is not needed The unit...

Page 14: ...ter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramcosafety com CHINA A11 No 1 Jinxi Road Qingshuipu Zhenhai Zhejiang Ningbo China 315221 Phone 86 574 87979390 Fax 86 574 87979391 saleschina euramcosafety com MADE IN THE USA Use with all US Firefighting literature ...

Reviews: