Calibration
The two switches on the sensor front serve as reference
Sensor Calibration
• Rotate the Light/Dark switch to LIGHT ON to activate the sensor when the object is in
measuring range.
• Set the object at the required detection distance and adjustment the sensitivity switch by
increasing the potentiometer until the orange LED light is lit.
• Remove the object and set sensitivity half-way between the detected point and maximum
potentiometer value.