background image

Rako RAVIR Installation, Programming and Operating Instructions

General

The Rako RAVIR is an Infra-red to RF interface designed to convert standard RC5 infra red 

signals to Rakom RF. The unit allows use of generally available IR transmitter devices to select 
lighting scenes on a Rako system. The RAVIR is fitted with an internal receiver but can also be  

used with an external IR receiver head allowing the unit to be positioned in a discrete location. 
The RAVIR requires the use of an external power supply

Before commencing installation of a Rako module please read this instruction manual carefully. 

Rako   Controls   Ltd   accepts   no   responsibility   for   damage   or   injury   caused   by   incorrect 
installation of a Rako product.

Mounting

Rako modules should be mounted in areas that are adequately ventilated, dry and outside of 
any enclosed metal casings that may interfere with the wireless signal.  Wherever possible the 

mounting bracket should be used.  

Whilst Rako modules are designed to be completely maintenance free the units should be 
mounted in an accessible location should there be a fault or re-addressing of the unit be 

necessary (see 'Set-up and Addressing')

Connections

Connect   the   RAVIR   module   according   to   the   wiring   diagram   overleaf.     Note   the   unit   is 

designed to be fed from a 9V or 12V DC power supply. 

Set-Up and Addressing

RAVIR modules can be programmed manually or by using RASOFT programming software.  The 

module needs to be addressed as a channel (preferably one not used by lighting modules) in 
the same Room as the lighting to be controlled.   When programming from RASOFT  it is 

possible to control up to 4 Rooms from one RAVIR, in which case the module should be 
addressed to a channel in the first Room to be controlled. To address a RAVIR using Rasoft  

refer to the appropriate programming guide supplied as a PDF with the programming interface 
(RA or RTC-Bridge etc.) or download from our website: 

www.rakocontrols.com

.

Manual Addressing from Wallplate or Handheld

To manually address a RAVIR follow the Initial Addressing of a Rako Receiver Module overleaf.

Configuring the RAVIR to match IR transmitters

The default address of the RAVIR is RC5 Base address 5 (VCR1) controlling a single Room.  If 

any other setting is required the set-up requires setting in Rasoft Pro (or original Rasoft).  From 
Rasoft Pro once the unit is addressed (see Set-up and Addressing) right click the device from 

within the Room Editor page and click Goto RAVIR (Infrared Module).  Click the Infrared Set-up 
tab and a menu will appear allowing the selection of different RC5 base addresses as well as the 

option allowing the RAVIR to control 2 or 4 Rooms with either a single or 4 Room increment.  
Note: the first Room will always be the Room to which the RAVIR has been addressed.  Should  

the user require the Hex Codes for devices such as a Phillips Pronto then click the check box 
'pronto codes' and the codes will appear in a new window.

Care and Maintenance

A Rako module contains no user serviceable parts. Should for any reason you need to contact us 
please contact us via our website 

www.rakocontrols.com

 or by phoning our customer help line on 

01634 226666.

Reviews: