Copyright © Shenzhen Rakwireless Technology Co., Ltd
ETDX1602241830
40
RAK475 Instruction manual
STRING
Character string
\r\n
ASCII
2
End character
The command is unsuccessfully carried out
ERROR
ASCII
5
ERROR
<CODE>
HEX
1
For details see ERROR list
\r\n
ASCII
2
End character
Remarks
4.6.5
Read Factory Defaults
Command
at+write_restoreconfig=<data_length>,<data_stream>\r\n
Description
Read Factory Defaults parameters configuration of the module, returning
structure is the same with reading user's configuration.
Parameter instruction
Parameter
Parameter value
Instruction
<data_length>
length
Written length of written configuration
parameter
<data_stream>
data
Written configuration parameter
Instruction for returned value
Parameter
Format
Length(byte)
Instruction
The command is successfully carried out
OK
ASCII
2
OK