www.raisecom.com
User Manual
120
Chapter 17
The configuraiton command under the e1Interface configuration
mode of remote RC952-FXE1.
17.1 clock-mode
[Command Format]
clock-mode {master|slave}
[Function]
Set the E1 clock mode.
[Default]
master
[Command mode]
Interface configuration mode.
[Application Example]
RC953-GESTM1
#
config
RC953-GESTM1(config)
#
remote ric 33
RC953-GESTM1(config- RC952FXE1/33)
#
interface e1
RC953-GESTM1(config- RC952FXE1/33-e1/1)
#
clock-mode slave
Set successfully.
17.2 crc-auto
[Command Format]
crc-auto
{enable|disable}
[Function]
Crc is enable or disable of framed e1.
[Default]
disable
[Command mode]
Interface configuration mode.
[Instructions]
It is disable under the clarity mode.
[Application Example]
RC953-GESTM1#
config