www.raisecom.com
User Manual
20
PCM30) or 11 channel (1E1 as PCM31), to user sub-card, and occupy 21-30/31 channel of the first
E1. RC3000 will automatically assign 14 channels to user sub-card, and occupy 17-30 channel of the
first E1
RC3000 does not cross connect idle channels except RC3000-2E1 (ADM). RC3000-2E1 (ADM)
cross connect the same idle channels of E1 1 and E1 2 to realize the transfer between E1 1 andE1 2.
RC will first use valid cross connect configuration information saved in memory, and erase invalid
configuration information automatically. Rules for cross connection are as follows:
a.
All configurations will be refreshed if the line-board is changed and all saved cross connect
information is invalid.
b.
When sub-card is pulled out, the corresponding cross connect information will be erased.
c.
If the same type sub-card is put into the same slot, system will restore cross connect information
saved in memory.
d.
If new type sub-card is put in, system will first distribute the idle channels of E1 1 and then
looking for other idle channels for distribution.
5.1.6 System and crossover setting
RC3000 has rich configuration information for any E1 interface and signaling interface to realize all
kinds of cross connect. Please refer to
appendix A. how to use Hyper Terminal to configure RC3000.
5.1.7 Device alarms
There are two kinds of alarms: 1. device alarms; 2. system alarms. Device alarms indicate E1 line
and optical interface alarms, and optical interface alarms include:
¾
LOS alarm at local
¾
LOF alarm at local
¾
Alarm when bit error ratio is more than 10
-3
/s at local
¾
Alarm when bit error ratio is more than 10
-6
/s at local
¾
LOS alarm at remote
¾
LOF alarm at remote
¾
Alarm when bit error ratio is more than 10
-3
/s at remote
¾
Alarm when bit error ratio is more than 10
-6
/s at remote
RC3000-OPT-2E1 includes LOS alarm at E1 interface as below:
¾
Bit error alarm at local optical interface
¾
Loss of 3E1 signal at local
¾
Loss of 3E1 signal at local
¾
Bit error alarm at remote optical interface
¾
Loss of 3E1 signal at remote
¾
Loss of 3E1 signal at remote
E1 interface alarms:
¾
LOS alarm
¾
LOF alarm
¾
AIS alarm
¾
CRC error alarm
¾
Remote alarm indicator