Raisecom
RC3000-15 (P100R001) Hardware Description
6 Ethernet switching card
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
50
LED
Color
Description
100M
(GE1/GE2
electrical
interface)
Green
GE1/GE2 electrical interface 100 Mbit/s LED
Green: the GE1/GE2 electrical interface is working at
100 Mbit/s.
Off: the GE1/GE2 electrical interface is working at 10
Mbit/s.
1000M
(GE1/GE2
electrical
interface)
Green
GE1/GE2 electrical interface 1000 Mbit/s LED
Green: the GE1/GE2 electrical interface is working at
1000 Mbit/s.
Off: the GE1/GE2 electrical interface is working at 100
Mbit/s or 10 Mbit/s.
SD
(GE1/GE2)
Green
GE1/GE2 optical interface signal LED
Green: optical signals are detected.
Off: no optical signals are detected.
LNK/ACT
(GE1/GE2 optical
interface)
Green
GE1/GE2 optical interface working LED
Green: the GE1/GE2 optical interface is properly
connected.
Off: the GE1/GE2 optical interface is improperly
connected or disconnected.
Blinking green: the GE1/GE2 optical interface is
receiving or sending data.
6.1.6 DIP switch
Table 6-5 lists configurations of the DIP switch on the SUB-ESW-2GE card.
Table 6-5
DIP switch on the SUB-ESW-2GE card
SW1
Function
Status
Description
No.
Name
1
NMS
Set management
mode.
ON
NMS-SLA, slave control device
OFF
NMS-AUTO, automatically recognizable
by slot number
2
BP
Set chassis and
backplane type.
ON
BP-3000, used on the RC3000-15
OFF
BP-3500E&006, used on the
OPCOM3500E and RC006-12
6.1.7 Specifications
Table 6-6 lists parameters of the ESW-2GE card.