6 Network management features
Raisecom Technology Co., Ltd.
20
–
Annex type
Coding mode
Max./Min. rate (64 Kbit/s)
autopam
3–89
When two G. interfaces are interconnected, the Annex type and coding mode of these two
interfaces should be identical. Otherwise, the link may be disconnected.
6.3 Loopback detection
Through loopback detection, you can enable/disable internal/external loopback on the G.
interface.
Figure 6-1
G. interface internal loopback (electrical interface data loopback)
Figure 6-2
G. interface external loopback (G. interface data loopback)
The loopback status includes internal loopback, external loopback, and no loopback.
6.4 Resetting device
You can reset the local or remote device through related commands. Configurations remain