background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISCOM2600G (A) Series 

Product Description 

(Rel_10) 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.raisecom.com

Summary of Contents for ISCOM2608G-2GE

Page 1: ...ISCOM2600G A Series Product Description Rel_10 www raisecom com ...

Page 2: ...ication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in Writing from Raisecom Technology Co Ltd is the trademark of Raisecom Technology Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders The information in this document ...

Page 3: ...and SFP modules and lists terms acronyms and abbreviations involved in this document Versions The following table lists the product versions related to this document Product name Hardware version Software version ISCOM2608G 2GE A V3 60 ISCOM2608G 2GE PWR A V3 60 ISCOM2624G 4GE A V3 60 ISCOM2624G 4GE PWR A V3 60 ISCOM2624G 4GE RPS A V3 60 ISCOM2624G 4C A V3 60 ISCOM2624G 4C PWR A V3 60 ISCOM2648G 4...

Page 4: ...at may help you solve a problem or save time General conventions Convention Description Times New Roman Normal paragraphs are in Times New Roman Arial Paragraphs in Warning Caution Notes and Tip are in Arial Boldface Buttons and navigation path are in Boldface Italic Book titles are in italics Lucida Console Terminal display is in Lucida Console Book Antiqua Heading 1 Heading 2 Heading 3 and Block...

Page 5: ...commercial release Added the ISCOM2624G 4GE RPS and ISCOM2648G 4GE RPS Issue 05 2016 05 15 Fifth commercial release Added the ISCOM2608G 2GE PWR and ISCOM2624G 4GE PWR Issue 04 2016 04 28 Fourth commercial release Added the ISCOM2648G 4GE and ISCOM2608G 2GE Fixed known bugs Issue 03 2015 11 30 Third commercial release Upgraded the software version to V3 10 Updated some features Issue 02 2015 11 05...

Page 6: ...rk network access 13 2 2 Residential area broadband access 14 3 System structure 16 3 1 Panels 16 3 1 1 Front panels 16 3 1 2 Rear panels 24 3 2 Interfaces 29 3 2 1 Service interfaces 29 3 2 2 Management interfaces 35 3 3 Power interfaces 36 3 3 1 DC power 36 3 3 2 AC power interface 36 3 3 3 RPS power interface 37 3 4 LEDs 38 3 4 1 ISCOM2608G 2GE 38 3 4 2 ISCOM2608G 2GE PWR 39 3 4 3 ISCOM2624G 4G...

Page 7: ...ations 57 5 1 Overall parameters 57 5 2 Laser safety class 59 5 3 Reliability specifications 60 5 4 EMC indexes 60 5 5 Safety standards 60 5 6 Environmental requirements 61 5 6 1 Storage environment 61 5 6 2 Transport environment 62 5 6 3 Operation environment 62 5 7 Standards and protocols 63 6 Appendix 65 6 1 Cables 65 6 1 1 Fiber 65 6 1 2 Ethernet cable 67 6 1 3 Ground cable 70 6 1 4 DC power c...

Page 8: ...e 3 8 Front panel of ISCOM2624G 4GE PWR AC DC 20 Figure 3 9 Front panel of the ISCOM2624G 4GE RPS AC 20 Figure 3 10 Front panel of the ISCOM2624G 4C AC 21 Figure 3 11 Front panel of the ISCOM2624G 4C DC 21 Figure 3 12 Front panel of the ISCOM2648G 4GE AC DC 22 Figure 3 13 Front panel of the ISCOM2648G 4GE RPS AC 22 Figure 3 14 Front panel of the ISCOM2648G 4C AC DC S 23 Figure 3 15 Front panel of ...

Page 9: ...terface 37 Figure 3 36 ISCOM2624G 4GE RPS AC power interface 37 Figure 3 37 ISCOM2648G 4GE RPS AC power interface 38 Figure 4 1 Installing brackets 50 Figure 4 2 Installing cage nuts 50 Figure 4 3 Installing guide rails 51 Figure 4 4 Installing device horizontally in rack 51 Figure 4 5 Installing wall mount brackets 52 Figure 4 6 Installing screws 52 Figure 4 7 Wall mount installation 53 Figure 4 ...

Page 10: ...t Raisecom Technology Co Ltd viii Figure 6 6 Ground cable 70 Figure 6 7 OT terminal 70 Figure 6 8 DC power cable 71 Figure 6 9 European AC power cable 73 Figure 6 10 American AC power cable 73 Figure 6 11 RJ45 Console cable 74 Figure 6 12 Wiring between DB9 female connector and RJ45 Console interface 75 ...

Page 11: ...ormation about 1000 Mbit s SFP electrical module 11 Table 1 11 Ordering information about 10 Gbit s SFP optical module 11 Table 3 1 Service interfaces 30 Table 3 2 Parameters of 10 Gbit s SFP optical interface 33 Table 3 3 Parameters of 1000 Mbit s SFP optical interface 34 Table 3 4 Parameters of 100 Mbit s SFP optical interface 34 Table 3 5 Parameters of 10 100 1000 Mbit s Ethernet electrical int...

Page 12: ... 61 Table 5 5 Atmosphere requirements during transport 62 Table 5 6 Atmosphere requirements during operation 62 Table 6 1 Fiber connectors 65 Table 6 2 Wiring of fiber 66 Table 6 3 Wiring of EIA TIA 568A and EIA TIA 568B standards 67 Table 6 4 Technical specifications of Ethernet cable 69 Table 6 5 Technical specifications of ground cable 71 Table 6 6 Technical specifications of DC power cable 72 ...

Page 13: ...uirements of all 1000 Mbit s access is designed for the access layer and can be used as aggregation devices for enterprises 1 2 Features Table 1 1 lists features of the ISCOM2600G series switch Table 1 1 Features Feature Description Basic features Accessing the device Console Telnet SSHv2 Managing users CLI Managing files BootROM system files configuration files Load and upgrade TFTP auto loading ...

Page 14: ...Option 18 Zero configuration Support IPv6 zero configuration PoE supported by PoE devices only IEEE 802 3af and IEEE 802 3at Common PoE configurations PD active check PoE scheduling QoS Trust priority Traffic classification IP priority DSCP priority and CoS priority and traffic policy rate limiting based on traffic policy re direction and re marking Priority mapping and queue scheduling Interface ...

Page 15: ... KeepAlive RMON LLDP DDM System log Alarm management Fan monitoring Hardware monitoring CPU monitoring Dual system Loopback Ping and Traceroute Performance statistics 1 3 Ordering information 1 3 1 Naming convention Figure 1 1 shows the naming convention for the ISCOM2600G series switch Figure 1 1 Naming convention Table 1 2 describes naming convention for the ISCOM2600G series switch Table 1 2 Na...

Page 16: ... support PoE E RPS redundant powers RPS Support RPS power Do not support RPS power F Power type AC Support AC power supply DC Support DC power supply AC S Support single AC power supply DC S Support single DC power supply AC D Support dual AC power supplies DC D Support dual DC power supplies AC_DC Support one AC one DC power supplies 1 3 2 Ordering information about device Table 1 3 lists orderin...

Page 17: ...ce provides 30 W ISCOM2608G 2GE PWR DC Support eight 10 100 1000 Mbit s RJ45 downlink interfaces Support two 1000 Mbit s Combo interfaces SFP 100 1000Base X interface and RJ45 10 100 1000Base T interface which cannot be enabled concurrently Support the SNMP interface for out of band network management Support 48 VDC power supply The 8 downlink interfaces have the following features Support PoE for...

Page 18: ... Support 48 VDC power supply The 24 downlink interfaces have the following features Support PoE for supplying power to the remote PD Support IEEE802 3af and IEEE802 3at Support non standard PDs Support a maximum output power of 30 W per interface Support a total power supply of up to 370 W through 24 interfaces each interface provides 15 4 W or 12 interfaces each interface provides 30 W ISCOM2624G...

Page 19: ... a total power supply of up to 370 W through 24 interfaces each interface provides 15 4 W or 12 interfaces each interface provides 30 W ISCOM2648G 4GE AC Support forty eight 10 100 1000 Mbit s RJ45 downlink interfaces Support four 1000 Mbit s Combo interfaces SFP 100 1000Base X interface and RJ45 10 100 1000Base T interface which cannot be enabled concurrently Support the SNMP interface for out of...

Page 20: ...ual 48 VDC power supplies ISCOM2648G 4C AC_DC Support forty eight 10 100 1000 Mbit s RJ45 downlink interfaces Support four 10 Gbit s SFP uplink interfaces it also supports 1000 Mbit s SFP modules Support the SNMP interface for out of band network management Support one 220 VAC power supply and one 48 VDC power supply The Combo interface refers to the two Ethernet interfaces one is an optical inter...

Page 21: ...el 4 Table 1 6 lists ordering information about wall mount accessories Table 1 6 Ordering information about wall mount accessories ERP code Component name Quantity 20 08 03 0048 01 ISCOM5104 B wall mount plate 2 20 04 00 0004 02 M3 6 flat head screw chrome 4 100 Mbit s SFP optical module Table 1 7 lists ordering information about the 100 Mbit s SFP optical module Table 1 7 Ordering information abo...

Page 22: ... Mbit s SFP electrical module Table 1 8 Ordering information about 100 Mbit s SFP electrical module Model Description USFP FE AN R SW 10 100BASE T auto negotiation Target transmission distance 100 m Enabled with auto negotiation SerDes interface 1000 Mbit s SFP optical module Table 1 9 lists ordering information about the 1000 Mbit s SFP optical module Table 1 9 Ordering information about 1000 Mbi...

Page 23: ...optical module RoHS compliant DDM RoHS compliant 1000 Mbit s SFP electrical module Table 1 10 lists ordering information about the 1000 Mbit s SFP electrical module Table 1 10 Ordering information about 1000 Mbit s SFP electrical module Model Description USFP GE R SW Transmission rate 1000 Mbit s Target transmission distance 100 m SerDes interface USFP GE AN R SW Transmission rate 10 100 1000 Mbit...

Page 24: ... Gbit s Target transmission distance 10 km Tx wavelength 1310 nm Dual fiber SM SFP optical module DDM RoHS compliant USFP 192 S2 SW SFP optical module Transmission rate 10 Gbit s Target transmission distance 40 km Tx wavelength 1550 nm DDM RoHS compliant USFP 192 S3 SW SFP optical module Transmission rate 10 Gbit s Target transmission distance 80 km Tx wavelength 1550 nm DDM RoHS compliant ...

Page 25: ...se park network access Residential area broadband access 2 1 Enterprise park network access As shown in Figure 2 1 in the enterprise park network access networking the ISCOM2600G series switch as an access device is connected downstream to data devices from enterprises campuses and residential areas and upstream to a Layer 3 aggregation device accessing and transmitting broadband voice wireless an...

Page 26: ...1 Enterprise park network access networking 2 2 Residential area broadband access As an access switch the ISCOM2600G series switch can work as a core switch for a small network As shown in Figure 2 2 the ISCOM2600G series switch is connected to the L3 aggregation switch through the 10GE interface and downstream to the 1000 Mbit s switch through the GE interface ...

Page 27: ...secom ISCOM2600G A Series Product Description 2 Networking applications Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 15 Figure 2 2 Residential area broadband access networking ...

Page 28: ... including the following sections Panels Interfaces Power interfaces LEDs 3 1 Panels Definition of the power supply is listed below AC single AC power supply DC single DC power supply AC DC single power supply single AC DC AC DC S single power supply single AC DC AC DC D dual power supplies dual AC DC AC_DC dual power supplies one AC one DC 3 1 1 Front panels ISCOM2608G 2GE AC Figure 3 1 shows the...

Page 29: ...vice uplink GE interfaces 9 10 7 SNMP interface and Console interface 8 PWR SYS and SNMP LEDs ISCOM2608G 2GE DC Figure 3 2 shows the front panel of the ISCOM2608G 2GE DC Figure 3 2 Front panel of ISCOM2608G 2GE DC 1 Ground terminal 2 Power connector 3 Service interfaces 1 8 LEDs 4 Service downlink interfaces 1 8 5 Service uplink SFP optical interfaces 9 10 6 Service uplink GE interfaces 9 10 7 SNM...

Page 30: ...plink GE interfaces 9 10 7 SNMP interface and Console interface 8 PWR SYS and SNMP LEDs ISCOM2608G 2GE PWR DC Figure 3 4 shows the front panel of the ISCOM2608G 2GE PWR DC Figure 3 4 Front panel of ISCOM2608G 2GE PWR DC 1 Power interface 2 Power switch 3 Service interfaces 1 8 and LEDs 4 Uplink interface LEDs 5 Service uplink SFP optical interfaces 9 10 6 Service uplink GE interfaces 9 10 7 SNMP i...

Page 31: ...NMP SYS and PWR LEDs 6 Mode button PoE mode switching ISCOM2624G 4GE AC Figure 3 6 shows the front panel of the ISCOM2624G 4GE AC Figure 3 6 Front panel of ISCOM2624G 4GE AC 1 Ground terminal 2 Power interface 3 Service interfaces 1 28 LEDs 4 Service downlink interfaces 1 24 5 Service uplink GE interfaces 25 28 6 Service uplink SFP optical interfaces 25 28 7 SNMP interface and Console interface 8 ...

Page 32: ... the front panel of the ISCOM2624G 4GE PWR AC DC Figure 3 8 Front panel of ISCOM2624G 4GE PWR AC DC 1 Service downlink interfaces 1 24 2 Service uplink GE interfaces 25 28 3 Service uplink SFP optical interfaces 25 28 4 SNMP interface and Console interface 5 Interface LEDs 6 POE PWR SYS and SNMP LEDs 7 Mode button ISCOM2624G 4GE RPS AC Figure 3 9 shows the front panel of the ISCOM2624G 4GE RPS AC ...

Page 33: ...4G 4C AC 1 Ground terminal 2 Power interface 3 Service interfaces 1 28 LEDs 4 Service downlink interfaces 1 24 5 Service uplink interfaces 25 28 6 SNMP interface and Console interface 7 PWR SYS and SNMP LEDs ISCOM2624G 4C DC Figure 3 11 shows the front panel of the ISCOM2624G 4C DC Figure 3 11 Front panel of the ISCOM2624G 4C DC 1 Ground terminal 2 Power interface 3 Service interfaces 1 28 LEDs 4 ...

Page 34: ...Service downlink interfaces 1 48 and LEDs 2 Service uplink SFP optical interfaces 49 52 3 Service uplink GE interfaces 49 52 LEDs ISCOM2648G 4GE RPS AC Figure 3 13 shows the front panel of the ISCOM2648G 4GE RPS AC Figure 3 13 Front panel of the ISCOM2648G 4GE RPS AC 1 Service downlink interfaces 1 48 and LEDs 2 Service uplink SFP optical interfaces 49 52 3 Service uplink GE interfaces 49 52 LEDs ...

Page 35: ...nterface SYS and PWR1 PWR2 4 SNMP interface and Console interface ISCOM2648G 4C AC DC D Figure 3 15 shows the front panel of the ISCOM2648G 4C AC DC D Figure 3 15 Front panel of the ISCOM2648G 4C AC DC D 1 Service downlink interfaces 1 48 and LEDs 2 Service uplink SFP optical interfaces 49 52 3 Uplink interfaces SNMP interface SYS and PWR1 PWR2 4 SNMP interface and Console interface ISCOM2648G 4C ...

Page 36: ...nterface and Console interface 3 1 2 Rear panels ISCOM2608G 2GE AC DC Figure 3 17 shows the rear panel of the ISCOM2608G 2GE AC DC Figure 3 17 Rear panel of ISCOM2608G 2GE AC DC ISCOM2608G 2GE PWR AC DC Figure 3 18 shows the rear panel of the ISCOM2608G 2GE PWR AC DC Figure 3 18 Rear panel of ISCOM2608G 2GE PWR AC DC ISCOM2624G 4C PWR AC Figure 3 19 shows the rear panel of the ISCOM2624G 4C PWR AC...

Page 37: ...the ISCOM2624G 4C PWR DC Figure 3 20 Rear panel of ISCOM2624G 4C PWR DC 1 Ground terminal 2 Power switch 3 Power interface ISCOM2624G 4GE AC DC Figure 3 18 shows the rear panel of the ISCOM2624G 4GE AC DC Figure 3 21 Rear panel of ISCOM2624G 4GE AC DC ISCOM2624G 4GE PWR AC Figure 3 19 shows the rear panel of the ISCOM2624G 4GE PWR AC Figure 3 22 Rear panel of ISCOM2624G 4GE PWR AC 1 Ground termina...

Page 38: ... Rear panel of ISCOM2624G 4GE PWR DC 1 Ground terminal 2 Power switch 3 Power interface ISCOM2624G 4GE RPS AC Take the AC model for example Figure 3 24 shows the rear panel of the ISCOM2624G 4GE RPS AC Figure 3 24 Rear panel of ISCOM2624G 4GE RPS AC 1 RPS power interface ISCOM2624G 4C AC DC Figure 3 25 shows the rear panel of the ISCOM2624G 4C AC DC Figure 3 25 Rear panel of ISCOM2624G 4C AC DC IS...

Page 39: ...ISCOM2648G 4GE DC Figure 3 27 shows the rear panel of the ISCOM2648G 4GE DC Figure 3 27 Rear panel of ISCOM2648G 4GE DC 1 Power interface 2 Ground terminal 3 SNMP interface and Console interface 4 SNMP SYS and PWR LEDs ISCOM2648G 4GE RPS AC Figure 3 28 shows the rear panel of the ISCOM2648G 4GE RPS AC Figure 3 28 Rear panel of the ISCOM2648G 4GE RPS AC 1 Power interface 2 Ground terminal 3 RPS pow...

Page 40: ...of the ISCOM2648G 4C AC S Figure 3 29 Rear panel of the ISCOM2648G 4C AC S 1 Ground terminal 2 Power interface ISCOM2648G 4C DC S Figure 3 30 shows the rear panel of the ISCOM2648G 4C DC S Figure 3 30 Rear panel of the ISCOM2648G 4C DC S 1 Ground terminal 2 Power interface ISCOM2648G 4C AC D Figure 3 31 shows the rear panel of the ISCOM2648G 4C AC D Figure 3 31 Rear panel of the ISCOM2648G 4C AC D...

Page 41: ...Rear panel of the ISCOM2648G 4C DC D 1 Ground terminal 2 Power interface ISCOM2648G 4C AC_DC Figure 3 33 shows the rear panel of the ISCOM2648G 4C AC_DC Figure 3 33 Rear panel of the ISCOM2648G 4C AC_DC 1 Ground terminal 2 Power interface 3 2 Interfaces The ISCOM2600G series switch provides external interfaces such as service interfaces management interfaces and power interfaces 3 2 1 Service inte...

Page 42: ...s the following adaptive electrical interfaces 10 100 1000BASE T ISCOM2608G 2GE PWR 2 1000 Mbit s Combo interface The SFP interface supports the following SFP optical modules 1000BASE X 100BASE FX The SFP interface supports the following SFP electrical modules 1000BASE T The GE interface supports the following adaptive electrical interfaces 10 100 1000BASE T ISCOM2624G 4GE 4 1000 Mbit s Combo inte...

Page 43: ...terface supports the following SFP electrical module 1000BASE T The GE interface supports the following adaptive electrical interface 10 100 1000BASE T ISCOM2624G 4C 4 The interface supports the following optical modules For 10 Gbit s SFP optical interfaces the available SFP optical module is 10GBASE X For 1000 Mbit s SFP optical interfaces the available SFP optical module is 1000BASE X For 1000 M...

Page 44: ...P electrical module 1000BASE T The GE interface supports the following adaptive electrical interface 10 100 1000BASE T ISCOM2648G 4C 4 The interface supports the following optical modules For 10 Gbit s SFP optical interfaces the available SFP optical module is 10GBASE X For 1000 Mbit s SFP optical interfaces the available SFP optical module is 1000BASE X For 1000 Mbit s SFP electrical interfaces t...

Page 45: ... 24 10 100 1000BASE T auto negotiation electrical interface ISCOM2624G 4C 24 10 100 1000BASE T auto negotiation electrical interface ISCOM2624G 4C PWR 24 10 100 1000BASE T auto negotiation electrical interface ISCOM2648G 4GE 48 10 100 1000BASE T auto negotiation electrical interface ISCOM2648G 4GE RPS 48 10 100 1000BASE T auto negotiation electrical interface ISCOM2648G 4C 48 10 100 1000BASE T aut...

Page 46: ...Table 3 4 Parameters of 100 Mbit s SFP optical interface Parameter Description Connector type LC PC Optical interface properties Depend on the selected SFP optical module Coding type 4B 5B Working mode Full duplex Standard IEEE 802 3 compliant 1000 Mbit s Ethernet electrical interface Table 3 5 lists parameters of the 10 100 1000 Mbit s Ethernet electrical interface Table 3 5 Parameters of 10 100 ...

Page 47: ...J45 10 100BASE T adaptive electrical interface You can conduct out of band management on the ISCOM2600G series switch through the SNMP interface RJ45 Console interface Table 3 7 lists parameters of the RJ45 Console interface Table 3 7 Parameters of RJ45 Console interface Parameter Description Connector type RJ45 Working mode Duplex UART Electrical feature RS 232 Baud rate 9600Baud SNMP interface T...

Page 48: ...0 series switch as shown in Figure 3 34 Figure 3 34 DC power interface Table 3 9 describes the DC power interface Table 3 9 DC power interface Power interface Type Print Usage DC power interface Fence terminal 48V power input terminal GND power input terminal Parameters Table 3 10 lists parameters of the DC power interface Table 3 10 Parameters of DC power interface Parameter Description Rated inp...

Page 49: ...Figure 3 35 AC power interface Parameters Table 3 11 lists parameters of the AC power interface Table 3 11 Parameters ofAC power interface Parameter Description Rated input voltage 220 VAC Voltage range 100 240 VAC 3 3 3 RPS power interface Introduction The ISCOM2624G 4GE RPS AC and ISCOM2648G 4GE RPS AC provide 12 V input RPS power interfaces You can purchase RPS power supplies additionally for b...

Page 50: ...ut terminal Specifications Table 3 13 lists parameters of the RPS power interface Table 3 13 Parameters of the RPS power interface Parameter Description Connector type 3 pin Phoenix connector with spaces of 5 08 mm Rated voltage 12 VDC Voltage range 11 64 12 36 VDC 3 4 LEDs 3 4 1 ISCOM2608G 2GE Table 3 14 lists LEDs on the ISCOM2608G 2GE Table 3 14 LEDs on ISCOM2608G 2GE LED Status Description LNK...

Page 51: ... the system is working improperly Blinking green every 1s the system has loaded the configuration file or the device is configured Off the system is working improperly 3 4 2 ISCOM2608G 2GE PWR Table 3 15 lists LEDs on the ISCOM2608G 2GE PWR Table 3 15 LEDs on ISCOM2608G 2GE PWR LED Status Description LNK ACT 1 8 Green Ethernet interface working status LED Green the interface is properly connected ...

Page 52: ... working status LED Green the interface is properly connected Blinking green the interface is receiving or sending data Off the interface is disconnected or improperly connected LNK ACT 25 28 Green Combo interface working status LED Green the interface is properly connected Blinking green the interface is receiving or sending data Off the interface is disconnected or improperly connected PWR Green...

Page 53: ...roperly connected Blinking green the interface is receiving or sending data Off the interface is disconnected or improperly connected PWR Green Power working status LED Green the power supply is normal Off the power supply is off or the power module is improperly installed SNMP Green SNMP interface working status LED Green the SNMP interface is properly connected Blinking green the SNMP interface ...

Page 54: ...the SNMP interface is properly connected Blinking green the SNMP interface is receiving or sending data Off the SNMP interface is disconnected or improperly connected SYS Green System working LED Green the system is working improperly Blinking green every 1s the system has loaded the configuration file or the device is configured Off the system is working improperly RPS Green RPS power LED Green t...

Page 55: ...working improperly 3 4 7 ISCOM2624G 4C PWR Table 3 19 lists LEDs on the ISCOM2624G 4C PWR Table 3 20 LEDs on ISCOM2624G 4C PWR LED Status Description ETH LNK ACT Port1 Port24 Green Ethernet interface working status LED Green the interface is properly connected Blinking green the interface is receiving or sending data Off the interface is disconnected or improperly connected POE POWER Port1 Port24 ...

Page 56: ...ISCOM2648G 4GE Table 3 21 LEDs on ISCOM2648G 4GE LED Status Description Port1 Port48 LNK ACT LED Green Ethernet interface working status LED Green the interface is properly connected Blinking green the interface is receiving or sending data Off the interface is disconnected or improperly connected Port1 Port48 SPEED LED Green Ethernet interface working rate LED Green the interface works at 1000 Mb...

Page 57: ...g green the interface is receiving or sending data Off the interface is disconnected or improperly connected Port1 Port48 SPEED LED Green Ethernet interface working rate LED Green the interface works at 1000 Mbit s Off the interface works at 100 Mbit s or stops working LNK ACT Port49 Port52 Green Combo interface working status LED Green the interface is properly connected Blinking green the interf...

Page 58: ...g or sending data Off the interface is disconnected or improperly connected LNK ACT Port49 Port52 Green 10 Gbit s SFP interface working status LED Green the interface is properly connected Blinking green the interface is receiving or sending data Off the interface is disconnected or improperly connected PWR1 2 Green Power working status LED Green the power supply is normal Off the power supply is ...

Page 59: ...he LEDs are in PoE status they are the power supply LEDs of the corresponding interfaces When the PoE LEDs are off they are switched to the LNK ACK status displaying the LNK ACK LEDs of the corresponding interfaces LEDs 1 24 are in LNK ACT status by default In this case the PoE LEDs are off If you press the Mode button the LEDs will be switched to the PoE status Then if you press the Mode button a...

Page 60: ...ardware The ISCOM2600G series switch adopts a 1U cartridge structure It can be easily installed in the following scenarios of a telecom equipment room Cabinet Workbench 4 1 1 Preparing for installation Environment conditions Table 4 1 lists requirements on the operation environment of the ISCOM2600G series switch Table 4 1 Requirements on operation environment Parameter Description Operating tempe...

Page 61: ...OM2608G 2GE 15 W ISCOM2608G 2GE PWR up to 141 W the PoE interfaces supply power up to 124 W ISCOM2624G 4GE 25 ISCOM2624G 4GE PWR up to 450 W the PoE interfaces supply power up to 370 W ISCOM2624G 4GE RPS 25 ISCOM2624G 4C 25 ISCOM2624G 4C PWR up to 450 the PoE interfaces supply power up to 370 W ISCOM2648G 4GE 45 ISCOM2648G 4GE RPS 45 ISCOM2648G 4C 45 The ISCOM2600 is supplied by multiple power sup...

Page 62: ...vice Therefore you have to install the device to a guide rail or a tray Prepare the guide rail or tray by yourself The ISCOM2648G 4C supports being installed in the rack with steps as below Step 1 Ensure that the rack is stable Step 2 Install two customized brackets on the two sides of the ISCOM2600G series switch respectively and fix them with screws as shown in Figure 4 1 Figure 4 1 Installing b...

Page 63: ...G 4C horizontally in the rack as shown in Figure 4 4 Figure 4 4 Installing device horizontally in rack Do not lay heavy objects or coverings on the ISCOM2600G series switch Wall mount installation At present only the ISCOM2608G 2GE supports wall mount installation The wall mount brackets and M3 6 screws used during installation are accessories Purchase them additionally as required The ISCOM2608G ...

Page 64: ...gure 4 5 shows how to install brackets to one side Do the same on the other side as shown in Figure 4 5 Figure 4 5 Installing wall mount brackets Step 3 Drill four holes on the wall according to the distance of the two holes on the brackets and the device width Keep the lines connected by the brackets horizontal and vertical and fix four screws to the wall as shown in Figure 4 6 Figure 4 6 Install...

Page 65: ...M2600G series switch Do not stare into the optical interface fiber connector or breakage of fiber directly Connect fiber as below Step 1 Remove the dustproof cover from the SFP optical interface and SFP optical module and insert the SFP optical module into the optical interface on the ISCOM2600G series switch as shown in Figure 4 8 Figure 4 8 Inserting SFP optical module Step 2 Remove the dustproo...

Page 66: ... Ethernet cable accordingly Step 2 Insert the RJ45 connector of the Ethernet cable into the Ethernet interface of the ISCOM2600G series switch and insert the other RJ45 connector of the Ethernet cable into the Ethernet interface of the peer device as shown in Figure 4 10 Figure 4 10 Connecting Ethernet cable Connecting ground cable Connecting the ground cable properly is an important guarantee for...

Page 67: ...ries switch is well grounded Step 2 Insert the C13 connector of the AC power cable into the AC power interface on the rear panel tightly Insert the power plug of the AC power cable into the AC power socket of the power sourcing equipment as shown in Figure 4 12 Figure 4 12 ConnectingAC power cable Connecting DC power Connect the DC power cable as below Step 1 Ensure that the ISCOM2600G series swit...

Page 68: ...the ISCOM2600G series switch Step 2 Insert the other end of the RJ45 Console cable into the RS 232 serial interface on a PC or maintenance terminal as shown in Figure 4 14 Figure 4 14 Connecting RJ45 Console cable 4 2 Installing software The ISCOM2600G series switch is installed with all necessary software before delivery so that it can be powered on immediately for use after hardware installation...

Page 69: ... requirements Standards and protocols 5 1 Overall parameters Table 5 1 lists overall parameters of the ISCOM2600G series switch Table 5 1 Overall parameters of the ISCOM2600G series switch Parameter Description Dimensions ISCOM2608G 2GE 260 Width 130 Depth 44 Height ISCOM2608G 2GE PWR 300 Width 220 Depth 44 Height ISCOM2624G 4C 440 Width 220 Depth 44 Height ISCOM2624G 4C PWR 440 Width 300 Depth 44...

Page 70: ...4GE PWR 5 0 ISCOM2624G 4GE RPS 2 6 ISCOM2624G 4C 2 6 ISCOM2624G 4C PWR 5 0 ISCOM2648G 4GE 4 3 ISCOM2648G 4GE RPS 4 3 ISCOM2648G 4C 4 3 Operating temperature altitude 0 1800 m 0 50 C Operating humidity 10 90 RH non condensing DC power Rated voltage 48 VDC Voltage range 36 to 72 VDC AC power Rated voltage 220 VAC Voltage range 100 240 VAC 50 60 Hz Lightning protection level AC power ISCOM2624G 4C 6 ...

Page 71: ...mode 2 kV in common mode Ethernet electrical interface 6 kV in indoor common mode Table 5 2 lists power input of the ISCOM2648G series switch Table 5 2 Power input of the ISCOM2648G series switch Model Power input ISCOM2648G 4GE AC 100 240 VAC 0 8 A 50 60 Hz ISCOM2648G 4GE DC 48 VDC 1 4 A ISCOM2648G 4GE RPS AC 100 240 VAC 0 8 A 50 60 Hz ISCOM2648G 4C AC S 100 240 VAC 0 9 A 50 60 Hz ISCOM2648G 4C D...

Page 72: ...the ISCOM2600G series switch should be no longer than 5 minutes Annually system mean repair rate 1 5 MTTR 2 hours MTBF 100000 hours 5 4 EMC indexes The ISCOM2600G series switch designed according to ETS 300 386 series and ETS 300 127 series of European Telecommunication Standards Institute ETSI has passed Electromagnetic Compatibility EMC tests 5 5 Safety standards The ISCOM2600G series switch com...

Page 73: ...4 Atmosphere requirements during storage Parameter Description Air pressure kPa 86 106 Temperature C 25 to 60 Relative humidity 10 90 Solar radiation W s 1120 Heat radiation W s 600 Wind speed m s 20 Waterproof environment We recommend keeping the ISCOM2600G series switch indoor on the following conditions No ponding on the ground No water dropping above the package box Away from any water leakage...

Page 74: ... 10 90 Solar radiation W s 1120 Heat radiation W s 600 Wind speed m s 20 Waterproof environment When transporting the ISCOM2600G series switch ensure the following prerequisites The package box is intact Rainproof measures are taken so that rain will not leak into the package box No ponding is inside the transport vehicle 5 6 3 Operation environment Atmosphere environment Table 5 6 lists atmospher...

Page 75: ...r Network Interface UNI Requirements and Framework MEF Technical Specification MEF 13 User Network Interface UNI Type 1 Implementation Agreement MEF Technical Specification MEF 17 Service OAM Requirements Framework MEF Technical Specification MEF 20 User Network Interface UNI Type 2 Implementation Agreement IEEE 802 1D 2004 Part 3 Media Access Control MAC Bridges IEEE 802 1Q 2005 Standard for Loca...

Page 76: ...y SDH RFC1349 Type of Service in the Internet Protocol Suite RFC2474 Definition of the Differentiated Services Field DS Field in the IPv4 and IPv6 Headers RFC2475 An Architecture for Differentiated Services RFC2597 Assured Forwarding PHB Group RFC2598 An Expedited Forwarding PHB RFC2698 A Two Rate Three Color Marker RFC3086 Definition of Differentiated Services Per Domain Behaviors and Rules for t...

Page 77: ... Acronyms and abbreviations 6 1 Cables The following cables are used when connecting the ISCOM2600G series switch Cables Ethernet cable Ground cable DC power cable AC power cable RJ45 Console cable 6 1 1 Fiber Introduction The ISCOM2600G series switch supports Single mode Fiber SMF and Multi mode Fiber MMF Table 6 1 lists fiber connectors available for the ISCOM2600G series switch Table 6 1 Fiber ...

Page 78: ...er connector Figure 6 1 LC PC fiber connector When connecting or removing the LC PC optical connector align the connector with the optical interface and do not rotate the fiber Operate the fiber as below Align the head of the fiber jumper with the optical interface and insert the optical fiber into the interface gently To remove the fiber press the latch on the connector press the fiber head inwar...

Page 79: ...ive to straight through cable mode and crossover cable mode Appearance Figure 6 2 shows the Ethernet cable Figure 6 2 Ethernet cable Technical specifications The Ethernet cables are divided into two types Straight through cable used to connect devices of different type such as between a PC and a switch or between a switch and a router Crossover cable used to connect devices of the same type such a...

Page 80: ...ite Blue White Blue PIN 6 Orange Green PIN 7 White Brown White Brown PIN 8 Brown Brown Both two RJ45 connectors of the 10 100 1000 Mbit s straight through cable follow EIA TIA568B standard wiring Figure 6 3 shows wiring of the 10 100 1000 Mbit s straight through cable Figure 6 3 Wiring of 10 100 1000 Mbit s straight through cable Figure 6 4 shows wiring of the 100 Mbit s crossover cable ...

Page 81: ...Figure 6 4 Wiring of 100 Mbit s crossover cable Figure 6 5 shows wiring of 1000 Mbit s crossover cable Figure 6 5 Wiring of 1000 Mbit s crossover cable Technical specifications Table 6 4 lists technical specifications of the Ethernet cable Table 6 4 Technical specifications of Ethernet cable Parameter Description Name CBL ETH RJ45 RJ45 D ...

Page 82: ...es you can name it CBL ETH RJ45 RJ45 2m 6 1 3 Ground cable Introduction The ground cable is used to connect the ISCOM2600G series switch to the ground Appearance The ground cable is composed of ground terminals and the coaxial cable The ground terminal is usually an OT non insulated terminal The coaxial cable is a yellow green copper soft flame retardant conducting wire Figure 6 6 and Figure 6 7 s...

Page 83: ...trand copper core conducting wire 1 25 mm2 Model Protective ground round pressed terminal M4 Cross sectional area of the conducting wire 16 15AWG 1 2 1 5 mm2 Length 1 m The ground cable cannot be longer than 30 m and should be as short as possible otherwise a ground bar should be used 6 1 4 DC power cable Introduction The DC power cable transmits 48 VDC power to the power interface on the ISCOM260...

Page 84: ...oltage sheathe of cable core pairs 2000 VAC 5min Insulation and withstanding voltage cable core 1500 VAC 5min Certification CCC RoHS Compliant 6 1 5 AC power cable Introduction The AC power cable transmits 220 VAC power to the power interface on the ISCOM2600G series switch and supplies power for the whole device The AC power cables used by the ISCOM2600G series switch vary with countries or regio...

Page 85: ...ns of European AC power cable Parameter Description Name POL AC European 3 pin C13 connector 0 75mm2 1 5m RoHS Color Outer Black PVC insulation layer Inner Blue N brown L and yellow green stripe E Connector 1 IEC60320 C13 connector Connector 2 European 3 pin plug Inner conductor cross sectional area 3 0 75 mm2 Length 1 5 m Table 6 9 lists technical specifications of the American AC power cable Tab...

Page 86: ...hen debug and maintain it through a PC The connectors at the two ends of the Console cable are as below RJ45 connector connected to the Console interface on the ISCOM2600G series switch DB9 female connector connected to the Console interface on the PC Appearance Figure 6 11 shows the RJ45 Console cable Figure 6 11 RJ45 Console cable Wiring Table 6 10 lists wiring of the RJ45 Console interface Tabl...

Page 87: ...9 female connector and the RJ45 Console interface on the ISCOM2600G series switch Figure 6 12 Wiring between DB9 female connector and RJ45 Console interface Technical specifications Table 6 11 lists technical specifications of the RJ45 Console cable Table 6 11 Technical specifications of RJ45 Console cable Parameter Description Name CBL RS232 DB9F RJ45 2m Color White Model Cat 3 UTP cable Connecto...

Page 88: ... 100 Mbit s SFP optical module Model Wavelength nm Laser type Rx type Tx optical power dBm Minimum overload point dBm Extinction ratio dB Rx sensitivity dBm Transmission distance km USFP 03 M D R SW 1310 LED FP PIN 20 to 10 10 10 29 2 USFP 03 S1 D R SW 1310 FP PIN 15 to 8 8 10 34 15 USFP 03 S2 D R SW 1310 FP DFB PIN 5 to 0 8 8 2 34 40 USFP 03 S3 D R SW 1550 DFB PIN 5 to 0 10 10 34 80 100 Mbit s SF...

Page 89: ... 5 to 3 0 9 17 0 55 USFP Gb S1 D R SW 1310 FP PIN 10 to 3 3 9 21 15 USFP Gb S2 D R SW 1550 DFB PIN 3 to 2 3 9 21 40 USFP Gb S3 D R SW 1550 DFB APD 3 to 2 9 9 30 80 USFP Gb EX D R SW 1550 DFB APD 0 5 9 9 30 120 1000 Mbit s SFP electrical module Table 6 15 lists parameters of the 1000 Mbit s SFP electrical module Table 6 15 Parameters of 1000 Mbit s SFP electrical module Model Application code Auto ...

Page 90: ... Control List ACL A series of ordered rules composed of permit deny sentences These rules are based on the source MAC address destination MAC address source IP address destination IP address interface ID etc The device decides to receive or refuse the packets based on these rules Auto negotiation The interface automatically chooses the rate and duplex mode according to the result of negotiation Th...

Page 91: ...cast storm caused by the data loop on the Ethernet ring When the link or device on the Ethernet ring fails services can be quickly switched to the backup line to enable services to be recovered in time F Frame It is a data transmission unit composed of several parts each of which has different functions Full duplex In a communication link both parties can receive and send data concurrently H Half ...

Page 92: ... of QinQ is to add a public VLAN tag to a packet with a private VLAN tag making the packet encapsulated with two layers of VLAN tags The packet is forwarded over the ISP s backbone network based on the public VLAN tag and the private VLAN tag is transmitted as the data part of the packet In this way the QinQ feature enables the transmission of the private VLANs to the peer end transparently There ...

Page 93: ...do not affect each other 6 4 Acronyms and abbreviations A ACL Access Control List AN Access Node APS Automatic Protection Switching ARP Address Resolution Protocol C CFM Connectivity Fault Management CoS Class of Service CPU Central Processing Unit CSMA CD Carrier Sense Multiple Access Collision Detection D DAI Dynamic ARP Inspection DFB Distributed Feed Back DiffServ Differentiated Service DRR De...

Page 94: ...an Telecommunications Standards Institute I IGMP Internet Group Management Protocol L LLDP Link Layer Discovery Protocol LOS Loss of Signal M MEF Metro Ethernet Forum MTBF Mean Time Between Failure MVR Multicast VLAN Registration N NGN Next Generation Network NNM Network Node Management NView NNM NView Network Node Management P PHB Per Hop Behavior PPPoE PPP over Ethernet PVC Permanent Virtual Cir...

Page 95: ...Co Ltd 83 SLA Service Level Agreement SP Strict Priority SSHv2 Secure Shell v2 STP Spanning Tree Protocol T TACACS Terminal Access Controller Access Control System TFTP Trivial File Transfer Protocol U UART Universal Asynchronous Receiver Transmitter UL Underwriter Laboratories UNI User Network Interface W WRR Weight Round Robin ...

Page 96: ...ss Raisecom Building No 11 East Area No 10 Block East Xibeiwang Road Haidian District Beijing P R China Postal code 100094 Tel 86 10 82883305 Fax 8610 82883056 http www raisecom com Email export raisecom com ...

Reviews: