Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
12 System management
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
532
12.9.2 Preparing for configurations
Scenario
After cable diagnosis is enabled, you can learn the running status of cables, locate and clear
faults, if any, in time.
Prerequisite
N/A
12.9.3 Configuring cable diagnosis
Configure cable diagnosis for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom(config)#test
cable-diagnostics
noshutdown enable
Enable the function of not restarting the
interface upon cable diagnosis.
2
Raisecom#test cable-
diagnostics
interface-
type interface-number
Enable cable diagnosis. The device
supports this configuration on multiple
interfaces.
When you enable the function of not restarting the interface upon cable diagnosis,
the interface that is in Up status will be restarted once and then obtain cable
diagnosis data. Then, when cable diagnosis is ongoing, the interface that is in Up
status will not be restarted but directly read cable diagnosis data saved in the buffer,
and the interface that is in Down status will obtain the length to the faulty point during
cable diagnosis. The newly inserted interface will automatically execute cable
diagnosis and save results in the buffer.
12.9.4 Checking configurations
Use the following commands to check configuration results.
No.
Command
Description
1
Raisecom#show cable-diagnostics
[
interface-type interface-number
]
Show results of cable
diagnosis.