12.7.5 Configuring temperature monitoring alarm
Configure temperature monitoring alarm for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#
alarm temperature
{ notifies |
syslog }
Enable abnormal temperature alarm.
3
Raisecom(config)#
alarm temperature
{ high
high
-
value
| low
low
-
value
|
notifies |
syslog }
Enable temperature monitoring alarm output and
configure temperature monitoring alarm output
modes.
The high temperature threshold (high-value) must
be greater than the low temperature threshold (low-
value).
The low temperature threshold (low-value) must be
smaller than the high temperature threshold (high-
value).
12.7.6 Configuring power supply alarm
Configure voltage monitoring alarm for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)# alarm
power-supply { notifies |
syslog }
Enable power supply alarm and
configure alarm output mode.
12.7.7 Clearing all hardware environment monitoring alarms
manually
Clear all hardware environment monitoring alarms manually for the ISCOM2600G-HI series
switch as below.