Configuring peer OAM event alarm
Configure the peer OAM event alarm for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#interface
interface-type interface-
number
Enter physical layer interface
configuration mode.
3
Raisecom(config-
gigaethernet1/1/1)#oam peer
event trap enable
Enable peer OAM event alarm to send
link monitoring events to the NMS.
(Optional) configuring OAM variable obtaining
OAM variable obtaining is a link monitoring method. By obtaining the current variable of the
peer, you can learn status of current link. IEEE802.3 Clause 30 defines and explains
supported variable and its denotation obtained by OAM in details. The variable takes object as
the maximum unit. Each object contains Package and Attribute. A package contains several
attributes. Attribute is the minimum unit of a variable. When getting an OAM variable, it
defines object, package, branch, and leaf description of attributes by Clause 30 to describe
requesting object, and the branch and leaf are followed by variable to denote object responds
variable request.
The ISCOM2600G-HI series switch supports obtaining OAM information and interface
statistics.
Configure OAM variable obtaining for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#show oam peer { link-
statistic | oam-info }
[
interface-type interface-
number
]
Obtain EFM OAM information
about the peer device or interface
statistical variable.
Peer variable cannot be obtained until EFM is connected.
9.2.6 Configuring EFM passive function
The EFM passive function can be configured regardless the ISCOM2600G-HI series
switch is in active or passive mode.
Configuring device to respond with EFM remote loop
Configure the ISCOM2600G-HI series switch to respond with EFM remote loop as below.