background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gazelle S3028i (A) 
Hardware Description 
(Rel_02) 

 

 

 

 

 

 

 

 

 

www.raisecom.com

Summary of Contents for Gazelle S3028i

Page 1: ...Gazelle S3028i A Hardware Description Rel_02 www raisecom com ...

Page 2: ...excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in Writing from Raisecom Technology Co Ltd is the trademark of Raisecom Technology Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders The information in this document is subject to c...

Page 3: ...o this document Product name Product version Hardware version Gazelle S3028i P100R001 A 00 or later Conventions Symbol conventions The symbols that may be found in this document are defined as follows Symbol Description Indicates a hazard with a medium or low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation that if not avoided ...

Page 4: ...folders and users are in boldface For example log in as user root Italic Book titles are in italics Lucida Console Terminal display is in Lucida Console Change history Updates between document versions are cumulative Therefore the latest document version contains all updates made to previous versions Issue 02 2013 08 30 Second commercial release Fixed bugs Modified print information of the power m...

Page 5: ...3 2 Uplink interface cards 6 2 3 3 Downlink interface cards 6 2 4 Mapping between interface cards and slots 7 2 5 LEDs 7 2 6 Alarm output interface 8 3 Power modules 10 3 1 Functions 10 3 2 Appearance and interfaces 10 3 3 Specifications 12 4 Cables 13 4 1 Serial interface cable 13 4 1 1 Introduction 13 4 1 2 Appearance 13 4 1 3 PIN definitions 14 4 1 4 Technical specifications 14 4 2 Fiber 15 4 2...

Page 6: ...1 4 6 Grounding cable 22 4 6 1 Introduction 22 4 6 2 Appearance 22 4 6 3 Technical specifications 23 5 Lookup table for interface and module parameters 25 5 1 Lookup table for interface parameters 25 5 1 1 1000BASE X SFP optical interface 25 5 1 2 100BASE FX SFP optical interface 25 5 1 3 1000BASE T electrical interface 26 5 1 4 10 100BASE TX electrical interface 26 5 1 5 Console interface 26 5 2 ...

Page 7: ...ting advanced ring network protection mechanism in the industry it provides fast switching and routing applications for aggregation layer of small and medium sized industrial networks The Gazelle S3028i has 2 slots for holding uplink interface cards where the 1000 Mbit s service card is supported It has 6 slots for holding downlink interface cards where the 100 Mbit s service card is supported The...

Page 8: ...lle S3028i Parameter Value Dimensions Width Depth Height 440 mm 360 mm 44 mm Power consumption Full optical interface 40 W Full electrical interface 30 W Weight 7 kg Operating temperature 40 C to 85 C Operating humidity 5 95 RH non condensing Power DC power Rated voltage 24 V 48 V DC Voltage range 20 72 V DC AC power Rated voltage 110 V 220 V AC 110 V 220 V DC Voltage range 85 264 V AC 77 370 V DC...

Page 9: ...ce cards and LEDs of the Gazelle S3028i Appearance Interface Interface card Mapping between interface cards and slot LEDs Alarm output interface 2 1 Appearance 2 1 1 Front appearance Figure 2 1 shows the front appearance of the Gazelle S3028i Figure 2 1 Front appearance of the Gazelle S3028i 1 LEDs and button 2 Interface card slot 3 RJ45 Console interface ...

Page 10: ...face SFP optical interface and 1 9 SC PC and ST PC optical interface 6 Downlink interface card S6 RJ45 electrical interface SFP optical interface and 1 9 SC PC and ST PC optical interface 7 Downlink interface card S7 RJ45 electrical interface SFP optical interface and 1 9 SC PC and ST PC optical interface 8 Downlink interface card S8 RJ45 electrical interface SFP optical interface and 1 9 SC PC an...

Page 11: ...arm interface 3 PIN Phoenix terminal 5 08 mm Output alarms POWER1 POWER2 Power interface 5 PIN Phoenix terminal 7 62 mm Input power The prints of AC power interface and DC power rated voltage vary with the power specifications 2 3 Interface card As listed in Table 2 2 there are two kinds of interface cards uplink interface cards and downlink interface cards Table 2 2 Interface cards Type of interf...

Page 12: ...he rate of the uplink interface is 1000 Mbit s According to the service type the interface card can be divided into 1000 Mbit s RJ45 interface card and 1000 Mbit s SFP interface card Figure 2 4 list the types of the uplink interface card Figure 2 4 Types of the uplink interface card 2 3 3 Downlink interface cards There are 6 slots for the downlink interface card A single slot contains 4 interfaces...

Page 13: ...he same as shown in Table 2 3 Table 2 3 LEDs on the Gazelle S3028i LED Print Color Description System status LED SYS Green Green the system is being restarted or working improperly Blinking green the system is working properly Off the system is working improperly Alarm LED ALM Red Red alarms are generated Off no alarms are generated Power 1 status LED PWR1 Green Green power supply 1 is normal Off ...

Page 14: ...us mode LED it indicates the status of the current interface By default the status is LNK ACT mode SPD mode Green the interface works at the highest rate Off the working rate of the interface is lower than the normal rate FDX HDX mode Green FDX mode Off HDX mode LNK ACT mode Green the line is properly connected Blinking green the line is receiving or sending data Off the line is disconnected or im...

Page 15: ...rated PIN 2 and PIN 3 are connected When no alarm is generated PIN 1 and PIN 2 are connected Table 2 4 lists parameters of the alarm output interface Table 2 4 Parameters of the alarm output interface Property Description Connector type 5 08 mm 3 PIN Phoenix terminal Electrical features Connected Disconnected ...

Page 16: ...mbedded with a DC power module or an AC power module Based on industrial standards it provides reliable dual power backup and meets strict specifications The power module has the following functions The DC power module support 24 V 48 V DC input The AC power module supports 110 V 220 V DC and 110 V 220 V AC input Support dual power backup Support power failure alarm Support overload protection and...

Page 17: ...s and usage of the interface terminals are listed in Table 3 1 Table 3 1 Descriptions of interfaces of the power module Print Description DC 48 24V Support 48 V 24 V DC input AC 220 110V DC220 110V Support 220 V 110 V AC DC input L POWER1 Connect to the L terminal of AC power 1 or the positive terminal of DC power 1 N POWER1 Connect to the N terminal of AC power 1 or the negative terminal of DC po...

Page 18: ...cifications Table 3 2 lists the specifications of the power module Table 3 2 Specifications of the power module Parameter Value DC power Rated voltage 24 V 48 V DC Voltage range 20 72 V DC AC power Rated voltage 110 V 220 V AC 110 V 220 V DC Voltage range 85 264 V AC 77 370 V DC Frequency 50 Hz 60 Hz ...

Page 19: ...45 Console interface and allows you to log in to the device The serial interface cable is used to connect the Console interface of the device and the RS 232 serial interface of the maintenance console and transmit configuration data The maintenance Console implements local debugging and maintenance through the Console interface The serial interface cable is an 8 PIN unshielded cable with its conne...

Page 20: ...RJ45 interface Figure 4 2 PIN definitions and connection relations of the RS 232 serial interface and RJ45 interface 4 1 4 Technical specifications Table 4 1 lists technical specifications of the serial interface cable Table 4 1 Technical specifications of the serial interface cable Item Description Name CBL RS232 DB9F RJ45 2m Color White Model Unshielded CAT3 flat cable Connector RJ45 connector a...

Page 21: ...he type of fiber connector and fiber length properly as required on site 4 2 2 Appearance Figure 4 3 shows the SC PC fiber connector Figure 4 3 SC PC fiber connector When connecting or removing the SC PC optical connector align the connector with the optical interface and do not rotate the fiber Pay attention to the following points Align the head of the fiber jumper with the optical interface and...

Page 22: ...sed part of the optical interface leaves the groove pull out the fiber Figure 4 5 shows the LC PC fiber connector Figure 4 5 LC PC fiber connector When connecting or removing the LC PC optical connector align the connector with the optical interface and do not rotate the fiber Note the following points Align the head of the fiber jumper with the optical interface and insert the optical fiber into ...

Page 23: ... of the same type such as between a PC and another PC between a switch and another switch between a router and another router between a PC and a router they are divided into the same group Table 4 3 lists the line order of EIA TIA 568A and EIA TIA 568B standards Table 4 3 Line order of EIA TIA568Aand EIA TIA568B standards Connector RJ45 EIA TIA568A EIA TIA568B PIN 1 White Green White Orange PIN 2 ...

Page 24: ... are named CBL ETH RJ45 RJ45 2m Straight through cables Both two RJ45 connectors of the straight through cable follow EIA TIA568B standard line order Figure 4 7 shows the line order of the straight through cable Figure 4 7 Line order of the straight through cable Crossover cable The line order of the 100 Mbit s crossover cable is different from that of the 1000 Mbit s crossover cable One RJ45 conn...

Page 25: ...s The crossover is PIN1 to PIN3 PIN2 to PIN6 PIN4 to PIN7 and PIN5 to PIN8 as shown in Figure 4 9 Figure 4 9 Line order of the 1000 Mbit s crossover cable 4 4 AC power cable 4 4 1 Introduction The AC power cable supplies 110 V 220 VAC power and 110 V 220 V DC power from the power souring equipment to the power interface of the Gazelle S3028i and then transmits power to the entire device ...

Page 26: ...mode three plug connector and 5 PIN Phoenix terminal as shown in Figure 4 10 Figure 4 10 European AC power cable The AC power cable which meets American standard is composed of the American standard three plug connector and 5 PIN Phoenix terminal as shown in Figure 4 11 Figure 4 11 American AC power cable 4 4 3 Technical specifications Table 4 6 lists specifications of the European standard AC pow...

Page 27: ...standard three plug connector 7 62 5PIN head RoHS Type Copper core multi strand power supply cable 18AWG 0 75 mm2 Length 1 5 m 4 5 DC power cable 4 5 1 Introduction The DC power cable supplies 24 V 48 V DC power from the power souring equipment to the power interface of the Gazelle S3028i and then transmits power to the entire device 4 5 2 Appearance The DC power cable is composed of Phoenix termi...

Page 28: ...rference When installing and using the device ensure that the grounding cable is properly connected otherwise personnel injury or equipment damage may be caused The grounding cable is used to connect the Gazelle S3028i to the ground 4 6 2 Appearance The grounding cable for the Gazelle S3028i is composed of wiring terminals and the coaxial cable The wiring terminal is usually an OT bare press termi...

Page 29: ...mized For example the customer requires a 2 m cable and you can name the cable PIL grounding cable Φ4 2m Standard Comply with the UL standard and meet RoHS requirements Conducting wire Yellow green multi strand copper core conducting wire 1 25 mm2 Electronic wire UL1007 or UL1005 is used Stripped end 10 mm length and plated with tin Insulation sleeve 3 5 1 75 black heat shrink tubing It is a 20 mm...

Page 30: ...The terminal inner radius is 4 mm The terminal outer radius is less than 8 mm The sheath inner radius is 2 1 mm The thickness of the soldering terminal is greater than or equal to 0 6 mm Intersecting area of the wire 16 15AWG 1 2 1 5 mm2 The Gazelle S3028i is delivered without the grounding cable You need to prepare or make grounding cables on site if needed The grounding cable cannot be longer th...

Page 31: ... module parameters 5 1 Lookup table for interface parameters 5 1 1 1000BASE X SFP optical interface Table 5 1 Specifications on the 1000BASE X SFP optical interface Parameter Value Connector type LC PC Optical interface properties Depend on the selected SFP optical module Coding type 8B 10B Transmission rate 1000 Mbit s Working mode Full duplex mode 5 1 2 100BASE FX SFP optical interface Table 5 2...

Page 32: ... mode Support full duplex mode and half duplex mode Cable specifications When the working mode is 10 Mbit s and 100 Mbit s you are recommended to use CAT5 or above Unshielded Twisted Pair UTP When the working mode is 1000 Mbit s you are recommended to use CAT6 UTP 5 1 4 10 100BASE TX electrical interface Table 5 4 Specifications on the 10 100BASE TX electrical interface Parameter Value Connector t...

Page 33: ...si on dista nce k m Interface Laser devic e Recei ver USFP Gb M I 850 830 870 17 9 0 9 5 to 3 0 55 LC PC dual mode bidirectional VCSE L PIN USFP Gb S1 I 1310 1260 1620 21 9 3 10 to 3 15 LC PC dual mode bidirectional FP PIN USFP Gb S2 I 1310 1260 1620 21 9 3 2 to 3 40 LC PC dual mode bidirectional DFB PIN USFP Gb S3 I 1550 1260 1620 22 9 3 0 to 5 80 LC PC dual mode bidirectional DFB APD USFP 03 M I...

Page 34: ...nterconnected Ethernet interfaces automatically select interface rate and duplex mode according to negotiation result C Clock Synchronism In China Synchronous Digital Hierarchy SDH works in hierarchical primary slave synchronization Namely a Primary Reference Clock PRC controls clock synchronization on the entire network through synchronization links of the synchronization distribution network On ...

Page 35: ...uter networking term which describes using multiple network cables ports in parallel to increase the link speed beyond the limits of any one single cable or port and to increase the redundancy for higher availability M Multi mode fiber In this fiber multi mode optical signals are transmitted Q QinQ QinQ is also called Stacked VLAN or Double VLAN extended from 802 1Q defined by IEEE 802 1ad recomme...

Page 36: ...for unit It takes 44 45 mm as basic unit namely 1 U 44 45 mm V VLAN Virtual Local Area Network VLAN is a protocol proposed to solve broadcast and security issues for Ethernet It divides devices in a LAN into different segment logically rather than physically thus implementing virtual work groups which are based on Layer 2 isolation and do not affect each other 6 2 Acronyms and abbreviations A AN A...

Page 37: ... Protocol L LACP Link Aggregation Control Protocol LOS Loss of Signal M MAC Medium Access Control MSTP Multiple Spanning Tree Protocol MVR Multicast VLAN Registration O OSPF Open Shortest Path First P PC Personal Computer PE Provider Edge PVST Per VLAN Spanning Tree R RH Relative Humidity RIP Routing Information Protocol RSTP Rapid Spanning Tree Protocol S SFP Small Form factor Pluggable SPD Surge...

Page 38: ...zelle S3028i A Hardware Description 6 Appendix Raisecom Technology Co Ltd 32 U UART Universal Asynchronous Receiver Transmitter UL Underwriter Laboratories V VLAN Virtual Local Area Network VTP VLAN Trunk Protocol ...

Page 39: ...Address Building 2 No 28 Shangdi 6th Street Haidian District Beijing P R China Postal code 100085 Tel 86 10 82883305 Fax 8610 82883056 http www raisecom com Email export raisecom com ...