Gazelle S1020i-LI (A) 

User Manual 

(Rel_02) 

 

 

 

 

 

 

 

 

 

www.raisecom.com

Summary of Contents for Gazelle S1020i-LI

Page 1: ...Gazelle S1020i LI A User Manual Rel_02 www raisecom com ...

Page 2: ...ication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in Writing from Raisecom Technology Co Ltd is the trademark of Raisecom Technology Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders The information in this document ...

Page 3: ...he product versions related to this document Product name Software version Hardware version Gazelle S1020i LI A 00 V3 60M Conventions Symbol conventions The symbols that may be found in this document are defined as below Symbol Description Indicate a hazard with a medium or low level of risk which if not avoided could result in minor or moderate injury Indicate a potentially hazardous situation th...

Page 4: ... path are in Boldface Italic Book titles are in italics Lucida Console Terminal display is in Lucida Console Book Antiqua Heading 1 Heading 2 Heading 3 and Block are in Book Antiqua Change history Updates between document versions are cumulative Therefore the latest document version contains all updates made to previous versions Issue 02 2010 05 30 Second commercial release Added the following two...

Page 5: ...W24 8 2 1 2 Gazelle S1020i 2GF 8GE LI DCW24 10 2 1 3 Gazelle S1020i 4GF 8GE LI DCW24 12 2 2 Interfaces 14 2 2 1 Interface types and usage 14 2 2 2 Button 15 2 3 Interface properties 15 2 3 1 1000BASE X SFP optical interface 15 2 3 2 10 100 1000BASE T electrical interface 16 2 3 3 Console interface 16 2 3 4 Alarm output interfaces 16 2 3 5 DI interface 17 2 4 LEDs 19 2 5 Power supply 20 2 5 1 Intro...

Page 6: ...itions 35 4 1 3 Power supply conditions 36 4 1 4 Static electricity conditions 36 4 1 5 Grounding conditions 36 4 1 6 Other conditions 36 4 2 Installing device 37 4 2 1 Installing device on guide rail 37 4 3 Grounding device 38 4 4 Connecting cables 39 4 4 1 Connecting Ethernet cable 39 4 4 2 Connecting fiber 39 4 4 3 Connecting power cable 41 4 5 Powering on device 41 4 6 Checking installation 42...

Page 7: ...Raisecom Gazelle S1020i LI A User Manual Contents Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd v 6 Appendix 48 6 1 Terms 48 6 2 Acronym and abbreviations 53 ...

Page 8: ...W24 13 Figure 2 6 Top appearance of the Gazelle S1020i 4GF 8GE LI DCW24 14 Figure 2 7 Alarm output interface 17 Figure 2 8 DI interface 18 Figure 2 9 DC power interface 20 Figure 2 10 Ground cable 23 Figure 2 11 OT terminal 23 Figure 2 12 RJ45 Console cable 25 Figure 2 13 PINs and wiring 25 Figure 2 14 Ethernet cable 26 Figure 2 15 Wiring of the straight through cable 27 Figure 2 16 Wiring of the ...

Page 9: ...A User Manual Figures Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd vii Figure 4 7 Inserting the fiber 40 Figure 4 8 Connecting the DC power connector 41 Figure 5 1 Location of the NView NNM system 47 ...

Page 10: ...the 10 100 1000BASE T electrical interface 16 Table 2 9 Parameters of the Console interface 16 Table 2 10 Parameters of the alarm output interface 17 Table 2 11 Digital input interface 18 Table 2 12 Configuring triggering condition 18 Table 2 13 Parameters of the DI interface 19 Table 2 14 LEDs 19 Table 2 15 Terminals on DC power interface 1 20 Table 2 16 Specifications of DC power supplies 21 Tab...

Page 11: ...ecifications of the DC power cable 29 Table 2 25 Type and usage of the fiber 29 Table 2 26 Wiring of the fiber 30 Table 3 1 Reliability indicators 33 Table 3 2 Environmental requirements 33 Table 4 1 Requirements for the operating environment 36 Table 4 2 Power supply requirements for operation 36 Table 4 3 Items to be checked after installation 42 ...

Page 12: ... the Gazelle S1020i LI adopts an all metal shell and fanless heat dissipation design features small size and low power consumption and is easy to install It is designed to meet requirements for industrial on site data backhaul and industrial automated controlling system so it can work stably for a long time in harsh environments The Gazelle S1020i LI supports industrial redundant ring network prot...

Page 13: ...er grade reliability Support a wide range of operating temperature from 40 to 75 C altitude 0 1800 m Be dampproof and corrosion resistant Support humidity of 5 95 in the operating environment non condensing Support the Digital Input DI interface and relay alarms Provide multiple interface types The uplink interface supports the SFP optical interface The downlink interface supports the RJ45 electri...

Page 14: ...rall power consumption Gazelle S1020i 2GF 4GE LI DCW24 6 W Gazelle S1020i 2GF 8GE LI DCW24 8 W Gazelle S1020i 4GF 8GE LI DCW24 12 W Weight without guide rail Gazelle S1020i 2GF 4GE LI DCW24 0 7 kg Gazelle S1020i 2GF 8GE LI DCW24 0 9kg Gazelle S1020i 4GF 8GE LI DCW24 1 0kg Operating temperature altitude 0 1800 m 40 to 75 C Working humidity 5 95 RH non condensing Protection class IP40 Power supply D...

Page 15: ...ion solving the problem of self loop and inner loop Interface protection implementing L2 data isolation Port mirroring Transparent transmission of L2CP Ring protection ITU T G 8032 ERPS IP service ARP DHCP Client DHCP Server DHCP Relay DHCP Snooping DHCP Option 82 Routing Route management QoS ACL rules Trusted CoS and DSCP priorities Traffic classification and traffic policies traffic rate limit r...

Page 16: ...road video monitoring system is used in hierarchical highway toll stations and specific transportation crossings in the cities etc It can accurately collect and record information about vehicles that pass the station and crossing Figure 1 2 shows the crossroad video monitoring system using the Gazelle S1020i LI After the aggregation switch in the police station is connected to the Gazelle S1020i L...

Page 17: ...odel Description Gazelle S1020i 2GF 4GE LI DCW24 Provide two 1000 Mbit s auto negotiation SFP optical interfaces Provide four 10 100 1000BASE T electrical interfaces Support outputting 1 ways of relay alarms Support 12 24 VDC power dual input Gazelle S1020i 2GF 8GE LI DCW24 Provide two 1000 Mbit s auto negotiation SFP optical interfaces Provide eight 10 100 1000BASE T electrical interfaces Provide...

Page 18: ...om Technology Co Ltd 7 Model Description Gazelle S1020i 4GF 8GE LI DCW24 Provide four 1000 Mbit s auto negotiation SFP optical interfaces Provide eight 10 100 1000BASE T electrical interfaces Provide one Digital Input DI interface Support outputting 1 ways of relay alarms Support 12 24 VDC power dual input ...

Page 19: ... This chapter describes the hardware structure of the Gazelle S1020i LI including the following sections Appearance Interfaces Interface properties Lookup table of optical module parameters LEDs Power supply Cables 2 1 Appearance 2 1 1 Gazelle S1020i 2GF 4GE LI DCW24 Front appearance Figure 2 1 shows the front appearance of the Gazelle S1020i 2GF 4GE LI DCW24 ...

Page 20: ...GE LI DCW24 Print Description LED PWR1 and PWR2 ALM SYS MGMT LNK ACT 1 6 SPEED 1 6 PWR power status LED ALM alarm LED SYS system status LED MGMT network management LED LNK ACT 1 6 GE optical electrical interface status LED SPEED 1 6 GE optical electrical interface rate LED Interface 1000M 1 4 100 1000M 5 6 1000M 1 4 service interface 10 100 1000BASE T auto negotiation Ethernet electrical interface...

Page 21: ...d 10 Figure 2 2 Top appearance of the Gazelle S1020i 2GF 4GE LI DCW24 1 Ground terminal 2 RST button 3 Console interface RJ45 4 Alarm output interface ALM 5 Power interface 2 PWR2 6 Power interface 1 PWR1 2 1 2 Gazelle S1020i 2GF 8GE LI DCW24 Front appearance Figure 2 3 shows the front appearance of the Gazelle S1020i 2GF 8GE LI DCW24 ...

Page 22: ...GE LI DCW24 Print Description LED PWR1 and PWR2 ALM SYS MGMT LNK ACT 1 10 SPEED 1 10 PWR power status LED ALM alarm LED SYS system status LED MGMT network management LED LNK ACT 1 10 GE optical optical interface status LED SPEED 1 10 GE optical electrical interface status LED Interface 1000M 1 8 100 1000M 9 10 1000M 1 8 service interface 10 100 1000BASE T auto negotiation Ethernet electrical inter...

Page 23: ...nce of the Gazelle S1020i 2GF 8GE LI DCW24 1 DI interface 2 RST button 3 Console interface RJ45 4 Alarm output interface ALM 5 Power interface 2 PWR2 6 Power interface 1 PWR1 7 Ground terminal 2 1 3 Gazelle S1020i 4GF 8GE LI DCW24 Front appearance of the Gazelle S1020i 4GF 8GE LI DCW24 Figure 2 5 shows the front appearance of the Gazelle S1020i 4GF 8GE LI DCW24 ...

Page 24: ...020i 4GF 8GE LI DCW24 Print Description LED PWR1 and PWR2 ALM SYS MGMT LNK ACT 1 12 PWR power status LED ALM alarm LED SYS system status LED MGMT network management LED LNK ACT 1 12 GE electrical interface status LED Interface 1000M 1 8 100 1000M 9 12 1000M 1 8 service interface 10 100 1000BASE T auto negotiation Ethernet electrical interface GE downlink electrical interface 100 1000M 9 12 service...

Page 25: ...e RJ45 4 Alarm output interface ALM 5 Power interface 2 PWR2 6 Power interface 1 PWR1 7 Ground terminal 2 2 Interfaces 2 2 1 Interface types and usage Service interfaces Table 2 4 lists interface types and usage of the Gazelle S1020i LI Table 2 4 Interface types and usage Interface type Description RJ45 10 100 1000BASE T auto negotiation electrical interface SFP GE SFP optical interface supporting...

Page 26: ...nterface used to output alarms DI interface 3 PIN Phoenix connector interface used to input digital signals Ground terminal Round pressed ground terminal used to connect the ground cable 2 2 2 Button Table 2 6 lists the button of the Gazelle S1020i LI Table 2 6 Button of the Gazelle S1020i LI Type Interface card RST reset button Shortly press it for less than 3s to restart the device Press it over...

Page 27: ...it s we recommend using Cat 6 or better STP cable 2 3 3 Console interface Table 2 9 lists parameters of the Console interface Table 2 9 Parameters of the Console interface Parameter Description Connector type RJ45 Duplex mode Duplex UART Electrical feature RS 232 Baud rate 9600 baud 2 3 4 Alarm output interfaces The alarm output interface is embedded with an electromagnetic relay When alarms are i...

Page 28: ...m output interface Table 2 10 Parameters of the alarm output interface Parameter Description Connector type 5 08 mm 3 pin phoenix terminal Electrical feature Connected Disconnected Maximum switching voltage 250 VAC 125 VDC Maximum switching current 3 A 250 VAC 30 VDC Maximum switching capability 90 W 2 3 5 DI interface The Gazelle S1020i LI DI interface adopts the 3 pin Phoenix connector with spac...

Page 29: ...30 V Low level the input voltage is 30 to 1 V After login you can configure the triggering condition of an external alarm to high level or low level in global configuration mode as described in Table 2 12 Table 2 12 Configuring triggering condition Step Command Description 1 Raisecom config Enter global configuration mode 2 Raisecom config alarm outside alarm num high low Configure the triggering ...

Page 30: ...the power supply is abnormal or off System status LED SYS Green Green the system is being started or working improperly Blinking green the system is working properly Off the system is being started or working improperly Alarm output LED ALM Red Red the system is being started or an alarm is generated such as DI input temperature threshold crossing abnormal interface status and abnormal power statu...

Page 31: ...nctions Support inputting 12 24 VDC power Support overload protection and reverse polarity protection Support overvoltage protection and surge protection Support NMS and electromagnetic relay alarm for battery failure 2 5 2 Appearance and interfaces Figure 2 9 shows the DC power interface on the Gazelle S1020i LI Figure 2 9 DC power interface The DC power interface on the Gazelle S1020i LIis a 2 p...

Page 32: ...4GF 8GE LI DCW24 12 W DC power supply Rated voltage 12 24 VDC Voltage range 10 36 VDC 2 6 Lookup table of optical module parameters Dual fiber bidirectional LC PC Table 2 17 Parameters of the GE 1250 Mbit s dual fiber bidirectional optical module Model Tx wavelen gth nm Rx wavelengt h nm Tx optical power EOL dBm Overl oadin g point dBm Extinc tion ratio dB Rx sensitivit y dBm Mode Transm ission di...

Page 33: ...6 SM 80 USFP Gb SS35 I 1550 1450 1510 2 0 to 3 0 3 0 9 0 26 SM 80 2 7 Cables 2 7 1 Ground cable Connecting the ground cable properly is an important guarantee for lightning protection anti electric shock and anti interference The Gazelle S1020i LI must be connected to the ground cable correctly during installation which helps avoid personal injury and equipment damage There is a ground terminal on...

Page 34: ...tions Table 2 19 lists technical specifications of the ground cable Table 2 19 Technical specifications of the ground cable Parameter Description Model recommended POL ground cable OT 1 5 4 stripped 16AWG D The letter D indicates the length which can be customized For example the customer requires a 2 m cable and you can name it POL ground cable OT 1 5 4 stripped 16AWG 2m Standard Comply with the ...

Page 35: ...ner diameter of sheath 3 4 mm Thickness of soldering lug 1 mm Cross sectional area of the conducting wire 12 10 AWG 4 6 mm2 The Gazelle S1020i LI is delivered without the ground cable If required make the ground cable on site according to technical specifications The ground cable cannot be longer than 30 m and should be as short as possible otherwise a ground bar should be used instead 2 7 2 Conso...

Page 36: ... 2 13 shows PINs and wiring of the Console cable Figure 2 13 PINs and wiring Technical specifications Table 2 21 lists technical specifications of the Console cable Table 2 21 Technical specifications of the Console cable Parameter Description Name CBL RS232 DB9F RJ45 B 2m RoHS Color Black Type Cat 3 UTP cable Connector RJ45 connector DB9 female connector Number of cores 4 Length 2 m ...

Page 37: ... 2 14 Ethernet cable Technical specifications The Ethernet cables have two types Straight through cable used to connect devices of different types such as between a PC and a switch or between a switch and a router Crossover cable used to connect devices of the same type such as between PCs between switches between routers or between a PC and a router they are of the same type Table 2 22 lists the ...

Page 38: ... RJ45 connectors of the straight through cable follow EIA TIA 568B standard wiring Figure 2 15 shows the wiring of the straight through cable Figure 2 15 Wiring of the straight through cable Crossover cable One RJ45 connector of the 100 Mbit s crossover cable follows EIA TIA 568A standard wiring the other RJ45 connector follows EIA TIA 568B standard wiring Figure 2 16 shows the wiring of the 100 M...

Page 39: ...45 D Connector RJ45 crystal header Model Cat 5 or better STP cable Number of cores 8 Length The letter D is the length which can be customized For example if the customer requires a 2 meter cable you can name it CBL ETH RJ45 RJ45 2m 2 7 4 DC power cable Introduction The DC power cable supplies 12 24 VDC power from the power souring equipment to the power interface on the Gazelle S1020i LI and then...

Page 40: ...nical specifications 2 7 5 Fiber Introduction The Gazelle S1020i LI supports the Single Mode Fiber SMF and Multi Mode Fiber MMF These two kinds of fiber are the same in appearance but different in color The yellow one is the SMF and the orange one is the MMF The Gazelle S1020i LI can be connected to the Optical Distribution Frame ODF or optical interfaces of other devices through fiber Table 2 25 ...

Page 41: ...pearance of the LC PC fiber connector Figure 2 18 LC PC fiber connector When connecting or removing the LC PC fiber connector align the connector with the optical interface and do not rotate the fiber Operate the fiber as below To connect the fiber align the header of the fiber with the optical interface and insert the fiber into the interface gently To remove the fiber press down the spring clip ...

Page 42: ...Hardware structure Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 31 Wiring relationship Local optical interface Direction of optical signals Peer optical interface connection Optical interface Rx Optical interface Tx ...

Page 43: ... security IEC 61588 Precision clock synchronization protocol for networked measurement and control systems IEEE 802 3 Information Technology IEEE1613 3 1 2 Laser safety class The laser beam in the fiber may hurt your eyes Do not stare into the optical interface during maintenance and installation According to the value of the laser Tx power the Gazelle S1020i LI laser belongs to Class 1 in terms o...

Page 44: ...T meets IEC 61000 4 4 level 4 requirements Damped oscillatory wave meets IEC 61000 4 18 level 3 requirements Surge impact meets IEC 61000 4 5 level 4 requirements Power frequency magnetic field meets IEC 61000 4 8 level 4 requirements The pulse magnetic field meets IEC 61000 4 9 level 5 requirements Damped oscillatory magnetic field meets IEC 61000 4 10 level 4 requirements Conducted Immunity CI m...

Page 45: ...elle S1020i LI A User Manual 3 Technical specifications Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 34 Parameter Description Environmental authentication Comply with EU RoHS standard ...

Page 46: ... shell When installing the Gazelle S1020i LI keep it away from adjacent electric devices Do not operate the Gazelle S1020i LI when your hands are wet or sweating Do not alter mechanical or electric parts of the Gazelle S1020i LI 4 1 2 Environmental conditions The hot air inside the Gazelle S1020i LI flows to cool the internal circuit through the front panel and heat dissipation holes on both side ...

Page 47: ... consumption RPS We recommend preparing a professional RPS in case of abnormal power supply 4 1 4 Static electricity conditions To prevent body static electricity from damaging the Gazelle S1020i LI wear the Anti Static Discharge ASD wrist strap properly any time when you contact the Gazelle S1020i LI 4 1 5 Grounding conditions The Gazelle S1020i LI must be grounded and the ground resistance shoul...

Page 48: ...guide rail We recommend guide rail installation When the Gazelle S1020i LI is taken out of the packing box it is already installed with the rail clip on the rear panel Install the Gazelle S1020i LI on the guide rail as below Step 1 Connect the rail clip to the guide rail as shown in Figure 4 1 Figure 4 1 Connecting the rail clip to the guide rail Step 2 Press the device to secure it to the guide r...

Page 49: ...e Connecting the ground cable properly is an important guarantee for lightning protection anti electric shock and anti interference The Gazelle S1020i LI must be connected to the ground cable correctly during installation which helps avoid personal injury and equipment damage Connect the ground cable as below Step 1 Loosen the screw of the ground terminal counterclockwise and keep the screw and wa...

Page 50: ...n Figure 4 4 Figure 4 4 Connecting the ground cable 4 4 Connecting cables 4 4 1 Connecting Ethernet cable Connect the Ethernet cable as below Step 1 Make the Ethernet cable as required Step 2 Align the Ethernet cable header with the Ethernet interface of the Gazelle S1020i LI and insert the Ethernet cable into the Ethernet interface gently as shown in Figure 4 5 Figure 4 5 Connecting the Ethernet ...

Page 51: ...y into the optical interface header of the optical connector or breakage of the fiber Inserting optical module Insert the SFP optical module into the optical interface on the Gazelle S1020i LI Figure 4 6 Inserting the optical module Connect LC PC fiber Step 1 Remove the plastic dustproof cover from the optical module and keep it for later use Step 2 To insert the fiber align the fiber header with ...

Page 52: ...nterface of the Gazelle S1020i LI is a 2 PIN Phoenix terminal Connect the DC power cable as below Step 1 Make the DC power cable according to specifications Step 2 Insert the DC power connector into the DC power interface of the Gazelle S1020i LI snuggly and tighten the screws at both sides of the connector as shown in Figure 4 8 Figure 4 8 Connecting the DC power connector Step 3 Connect the othe...

Page 53: ...ct and neat Check 7 The curvature radius of an optical fiber should be 20 times greater than the diameter In general it should be greater than 40 mm Check 8 The wiring of the power cable and ground cable should comply with engineering design documents to facilitate capacity expansion Check 9 Power cables and signal cables are laid separately Check 10 No stains or scratches on the surface of the de...

Page 54: ...he Console interface connecting a terminal or a PC that runs the terminal emulation program This management mode is based on the local Console interface without relying on the service network Therefore even though the service network fails you can configure and manage the Gazelle S1020i LI through the Console interface Telnet management The Telnet protocol one of the TCP IP protocol stack is a sta...

Page 55: ...h SNMPv1 SNMPv2c also uses community name authentication mechanism SNMP V2c supports more operation types data types and errored codes and thus better identifying errors SNMPv3 uses User based Security Model USM and View based Access Control Model VACM security mechanisms You can configure authentication and encryption to provide higher security for communication between the SNMP NMS and SNMP agen...

Page 56: ...fecting packets forwarding You can use this function to monitor the receiving and sending status of a certain port and analyze the network or fault status The Gazelle S1020i LI supports port mirroring based on ingress port or egress port When port mirroring is enabled packets on the ingress egress mirroring port will be mirrored to the monitor port The monitor port and mirroring port cannot be the...

Page 57: ... service Data center enable you to manage devices uniformly conducting operations such as upgrade backup restoration rollback and activation and meanwhile enable you to manage upgradable files back up files operations and generated logs ensuring that the backup operation is easy simple and with high security Data storage save logs history alarms and performance data from database as viewable files...

Page 58: ...Raisecom Gazelle S1020i LI A User Manual 5 Management and maintenance Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 47 Figure 5 1 Location of the NView NNM system ...

Page 59: ...avoid the maintenance and operation risks when the fiber is pulled out or the output power is over great Auto negotiation The interface automatically chooses the rate and duplex mode according to the result of negotiation The auto negotiation process is the interface adapts its rate and duplex mode to the highest performance according to the peer interface that is both ends of the link adopt the h...

Page 60: ...matically infeasible D Dynamic ARP Inspection DAI A security feature that can be used to verify the ARP data packets in the network With DAI the administrator can intercept record and discard ARP packets with invalid MAC address IP address to prevent common ARP attacks Dynamic Host Configuration Protocol DHCP A technology used for assigning IP address dynamically It can automatically assign IP add...

Page 61: ... NIC and other organizations IANA also maintains a database of assigned protocol identifiers used in the TCP IP suite including autonomous system numbers Internet Engineering Task Force IETF A worldwide organization of individuals interested in networking and the Internet Managed by the Internet Engineering Steering Group IESG the IETF is charged with studying technical problems facing the Interne...

Page 62: ...teway dynamic routing protocol which is used to decide the route in an Autonomous System AS Optical Distribution Frame ODF A distribution connection device between the fiber and a communication device It is an important part of the optical transmission system It is mainly used for fiber splicing optical connector installation fiber adjustment additional pigtail storage and fiber protection P Passw...

Page 63: ...rded and the network runs high efficiently Depending on the specific system and service it may relate to jitter delay packet loss ratio bit error ratio and signal to noise ratio R Rapid Spanning Tree Protocol RSTP Evolution of the Spanning Tree Protocol STP which provides improvements in the speed of convergence for bridged networks Remote Authentication Dial In User Service RADIUS RADIUS refers t...

Page 64: ...ping VLAN mapping is mainly used to replace the private VLAN Tag of the Ethernet service packet with the ISP s VLAN Tag making the packet transmitted according to ISP s VLAN forwarding rules When the packet is sent to the peer private network from the ISP network the VLAN Tag is restored to the original private VLAN Tag according to the same VLAN forwarding rules Thus the packet is sent to the des...

Page 65: ... Handshake Authentication Protocol CIDR Classless Inter Domain Routing CIR Committed Information Rate CIST Common Internal Spanning Tree CLI Command Line Interface CoS Class of Service CPU Central Processing Unit CRC Cyclic Redundancy Check CSMA CD Carrier Sense Multiple Access Collision Detection CST Common Spanning Tree D DAI Dynamic ARP Inspection DBA Dynamic Bandwidth Allocation DC Direct Curr...

Page 66: ...CS Frame Check Sequence FE Fast Ethernet FIFO First Input First Output FTP File Transfer Protocol G GARP Generic Attribute Registration Protocol GE Gigabit Ethernet GMRP GARP Multicast Registration Protocol GVRP Generic VLAN Registration Protocol H HDLC High level Data Link Control HTTP Hyper Text Transfer Protocol I IANA Internet Assigned Numbers Authority ICMP Internet Control Message Protocol I...

Page 67: ... Unit LAN Local Area Network LCAS Link Capacity Adjustment Scheme LLDP Link Layer Discovery Protocol LLDPDU Link Layer Discovery Protocol Data Unit M MAC Medium Access Control MDI Medium Dependent Interface MDI X Medium Dependent Interface cross over MIB Management Information Base MSTI Multiple Spanning Tree Instance MSTP Multiple Spanning Tree Protocol MTBF Mean Time Between Failure MTU Maximum ...

Page 68: ...DS PPPoE Active Discovery Session confirmation PAP Password Authentication Protocol PDU Protocol Data Unit PE Provider Edge PIM DM Protocol Independent Multicast Dense Mode PIM SM Protocol Independent Multicast Sparse Mode Ping Packet Internet Grope PPP Point to Point Protocol PPPoE PPP over Ethernet PTP Precision Time Protocol Q QoS Quality of Service R RADIUS Remote Authentication Dial In User S...

Page 69: ...quisition SF Signal Fail SFP Small Form factor Pluggable SFTP Secure File Transfer Protocol SLA Service Level Agreement SNMP Simple Network Management Protocol SNTP Simple Network Time Protocol SP Strict Priority SPF Shortest Path First SSH Secure Shell STP Spanning Tree Protocol T TACACS Terminal Access Controller Access Control System TC Transparent Clock TCP Transmission Control Protocol TFTP T...

Page 70: ...LI A User Manual 6 Appendix Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 59 V VLAN Virtual Local Area Network VRRP Virtual Router Redundancy Protocol W WAN Wide Area Network WRR Weight Round Robin ...

Page 71: ...ss Raisecom Building No 11 East Area No 10 Block East Xibeiwang Road Haidian District Beijing P R China Postal code 100094 Tel 86 10 82883305 Fax 8610 82883056 http www raisecom com Email export raisecom com ...