39
English
RAIS/
attika
- User manual for VIVA L Gas
Commissioning
Check functioning of pilot light.
See User Instructions for use of remote control.
1. Start the pilot light.
2. Check that the pilot light remains ignited.
3. Turn off the pilot light.
Check the functioning of the main burner.
1. Turn on the pilot light
2. Turn on the main burner.
3. Check that the cross-ignition from the pilot light to the main burner oc-
curs easily and that the main burner and pilot light remain ignited.
4. Check that the secondary burner's functions work.
5. Turn the stove off entirely.
Pressure Test
The stove is preset to provide the correct amount of heat (kW) as de-
scribed under specifications. There is usually no need for further adjust-
ment. "Inlet pressure" and ”Burner pressure” must
ALWAYS
be meas-
ured. And corrected if necessary.
1. Close the gas valve (Main Valve Knob)
2. Open the ”Inlet pressure tap” on the gas valve and connect a manome-
ter.
3. Check that the pressure measured concurs with the prescribed pressure
from the gas supply company.
4. Carry out the test when the stove is at maximum heat output, including
the secondary burners and when the stove only has the pilot light
ignited.
5. If the pressure is low, check that the gas supply pipes are the correct size.
6. If the inlet pressure is too high (more than 5 mbar over), the gas supply
must be corrected before the stove is commissioned.
7. The screw for the "Outlet pressure tap" on the gas valve is loosened and
a manometer connected
8. Check that the pressure measured concurs with the pressure stated on
the rating plate.
9. The value measured must be within ± 10% of the stated pressure. cor-
rect as necessary (see gas valve diagram)
Note. After the pressure test and removal of the manometer, the
screws in the "pressure tap" should be retightened. Check the
system for gas leaks.
Summary of Contents for Viva 100 L Gas
Page 34: ...34 4 3 5 Deutsch RAIS attika Bedienungsanleitung für VIVA L GAS Scheit 3 Scheit 4 Scheit 5 ...
Page 35: ...35 6 A B Deutsch RAIS attika Bedienungsanleitung für VIVA L GAS Scheit 6 Scheit A Scheit B ...
Page 40: ...40 Deutsch RAIS attika Bedienungsanleitung für VIVA L GAS ...
Page 75: ...75 Deutsch RAIS attika Bedienungsanleitung für VIVA L GAS D O P ...
Page 76: ...1 POSITIV V I VA L G A S GB ...
Page 108: ...34 4 3 5 English RAIS attika User manual for VIVA L Gas Log 3 Log 4 Log 5 ...
Page 109: ...35 6 A B English RAIS attika User manual for VIVA L Gas Log 6 Log A Log B ...
Page 114: ...40 English RAIS attika User manual for VIVA L Gas ...
Page 122: ...48 ...
Page 123: ...49 ...
Page 149: ...75 English RAIS attika User manual for VIVA L Gas D O P ...
Page 150: ...1 POSITIV V I VA L G A S F ...
Page 188: ...40 Français RAIS attika Manuel d utilisateur pour VIVA L Gas ...
Page 223: ...75 Français RAIS attika Manuel d utilisateur pour VIVA L Gas ...
Page 224: ...1 POSITIV V I VA L G A S NL ...
Page 256: ...34 4 3 5 Vlaams RAIS attika Gebruikershandleiding voor VIVA L Gas Blok 3 Blok 4 Blok 5 ...
Page 257: ...35 6 A B Vlaams RAIS attika Gebruikershandleiding voor VIVA L Gas Blok 6 Blok A Blok B ...
Page 262: ...40 Vlaams RAIS attika Gebruikershandleiding voor VIVA L Gas ...
Page 297: ...1 POSITIV V I VA L G A S I ...
Page 329: ...34 4 3 5 Italiano RAIS attika Istruzioni d uso per VIVA L GAS Ciocco 3 Ciocco 4 Ciocco 5 ...
Page 330: ...35 6 A B Italiano RAIS attika Istruzioni d uso per VIVA L GAS Ciocco 6 Ciocco A Ciocco B ...
Page 335: ...40 Italiano RAIS attika Istruzioni d uso per VIVA L GAS ...
Page 370: ...75 Italiano RAIS attika Istruzioni d uso per VIVA L GAS D O P ...
Page 374: ...1 2 3 4 5 6 7 8 Viva 100 L Gas Viva 120 L Gas Viva 160 L Gas ...
Page 375: ...82 1 2 3 4 5 6 7 8 9 10 11 12 14 13 15 Viva 100 L G Gas Viva 120 L G Gas Viva 160 L G Gas ...