Rainfresh MEGA 8 User Manual Download Page 1

MEGA 8

 

WATER FILTRATION AND DISINFECTION SYSTEM

  

USER MANUAL

 

 

Thank you for purchasing a Rainfresh product  

We are committed to ensuring that you are 

totally satisfied

 

If you have any questions or concerns while installing, operating or maintaining your new 

system, 

please contact us !

  

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 
 
 
 
 

 
 
 

QUESTIONS?

 

 

Canada Toll Free

 

1800 667 8072 

Toronto and Area

 

(905) 884 9388 

 

 

(Monday to Friday 8:00 AM to 5:00 PM EST)

 

 
 
 
 
 

[email protected]

 

 
 
 

 

www.rainfresh.ca 

CONTENTS 

A.

 

Introduction .............................................2 

B.

 

Safety Instructions ...................................2 

C.

 

Water Quality Requirements ...................3 

D.

 

Installation ...............................................3 

E.

 

Disinfection Procedure ............................6 

F.

 

Ballast Features ........................................7 

G.

 

Operation and Maintenance ....................7 

a.

 

Winterizing the system .....................9 

H.

 

Troubleshooting .......................................9 

I.

 

Technical Specifications ...........................9 

J.

 

Parts List ...................................................10 

K.

 

Warranty ..................................................10 

Tested and Certified by CSA International to CSA Standard 
B483.1, to NSF/ANSI Standard 61 for material and structural 
requirements only, and to NSF/ANSI 372 for lead-free 
requirements 

_________________________________________________ 

Additional testing and verification for UV dose performed by 
independent laboratory. 

 

Summary of Contents for MEGA 8

Page 1: ...rainfresh ca CONTENTS A Introduction 2 B Safety Instructions 2 C Water Quality Requirements 3 D Installation 3 E Disinfection Procedure 6 F Ballast Features 7 G Operation and Maintenance 7 a Winteriz...

Page 2: ...plug Never pull the cord o Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber during service o Do not touch the lamp or quartz dome by hand Hold the lamp and...

Page 3: ...h turbidity a back washable sediment filter is recommended as a pre filter We highly recommend a water test to confirm that your water quality is suitable for UV disinfection Rainfresh can test your w...

Page 4: ...recommended to build a bypass around the system so that you can still have untreated water in the house in case of unit malfunction or if you need to remove the unit for service Fittings Required for...

Page 5: ...gently rotate the dome while pushing in until it goes past the nut O ring 515 and touches the inside top end of the gland nut See Fig 5 Tip Rotate dome while pushing IN Fig 4 5 6 Carefully slide the q...

Page 6: ...hlorine and then shut the faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot wat...

Page 7: ...il rSET is displayed Release button and the ballast will emit a long beep to confirm reset Green LED will come on and red LED will turn OFF Display will show 365 again G OPERATION AND MAINTENANCE Your...

Page 8: ...ff supply valve before the unit and then unplug unit from electrical outlet Open a faucet to depressurize the MEGA8 system and turn off the valve at the outlet port to isolate it WARNING DO NOT LOOK D...

Page 9: ...s Install a temperature controlled purge valve on the UV outlet UV lamp ends seem burnt after some time This is normal As long as the UV lamp lights a little burn mark at the ends is normal and there...

Page 10: ...n material or workmanship The Ultraviolet lamp is warranted for a period of thirty 30 days from the date of purchase against defects in materials and workmanship The company s obligation under this wa...

Reviews: