The salt tank is pre-connected to the control head.  Lift the cabinet lid and add about 5 gallons of water in the salt 
tank. This is not a critical level but just helps with the process for the first regeneration. Then add 2 bags (20 Kg 
bags) of salt to start with. 

DO NOT ADD MORE THAN 2 BAGS OF SALT 

to prevent salt bridging. 

 

Turn main house shut-off valve on slightly and watch for leaks. Ensure a faucet is on somewhere and that its aerator 
is removed to avoid clogging from loosened scale in the pipes. If you have no leaks, proceed to the next steps.  

Turn on the water supply

 

 

Using the Allen key (included), 

turn the bypass inlet slightly

 (refer to 

fig 2

) to allow water to run into the unit. The 

water should initially fill the tank slowly. Once the tank is full of water, you can open valve fully. This prevents resin 
from being pushed up into the control head by the initial surge of water going in.  

 

Make sure there are no leaks in your plumbing before proceeding. 

 

At the nearest cold treated water tap remove the faucet screen and open the faucet. 
Using the Allen key (included), open the outlet side of the bypass valve and let water 
run a few minutes or until the system is free of any air or foreign material resulting 
from the plumbing work.  Close the water tap when water runs clean, and then proceed 
to start up instructions. 

 

Connect the control valve to the power adapter (

fig 7

) & connect the adapter to the 

power supply.  

NOTE: Your unit is not yet ready for service until you complete manual 
regeneration (see pages 7-11)

 

 

E.

 

START UP & PROGRAMMING 

The  control  valve  is  controlled  with  simple,  user-friendly  electronics 
displayed on an LCD screen.   

 

When  power  is  first  supplied,  the  valve  electronics  may  take  up  to  two 
minutes  to  initialize.    During  this  time  the  screen  will  show  “INTIALIZING 
WAIT  PLEASE”.    Do  not  touch  any  buttons  at  this  time.    When  the  valve 
reaches  the  service  position,  it  will  display  the  following  information  in 
sequence:

  

 

1.

 

Date & Time 

2.

 

Capacity (

gal of water that can be used between 

regenerations

3.

 

Volume Remaining (

gal of water left before regeneration 

begins

4.

 

Regeneration Time (

Time of day when regeneration starts

5.

 

Last Regeneration Date (

Last date when system regenerated

)

 

6.

 

Current Flow Rate (GPM) (

flow rate of water being currently 

used

)

 

7.

 

Peak Flow Rate (GPM) (

Max recorded flow rate of the water

)

The control valve has a display screen and 4 buttons 

 

 

 

 

 

 

 

 

 

 

MENU BUTTON

 

 

The function of this key 
is to enter the level one 
programming mode 
where the valve settings 
can be adjusted. 

SET / REGEN BUTTON

 

 

This button has two functions.  The first is to initiate 
a manual regeneration by holding the button for 3 
or more seconds.  The second function is while in 
programming mode, pressing this key allows the 
user to change the value of each setting. 

UP / DOWN

 

These buttons are used to 
increase or decrease the value 
of the settings while in the 
programming mode. 

FOR VIDEO INSTRUCTIONS ON PROGRAMMING 

Scan QR code  

 

or visit 

http://rainfresh.ca/how_to_videos.php#program 

 
 
 
 

Fig 7 

Summary of Contents for 30C

Page 1: ...1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS A System Specifications 2 B How Your Water Conditioner Works 2 C Safety Precautions Cautions 2 D Installation...

Page 2: ...into the water When the capacity of the resin to trap hardness minerals is exhausted the unit is re charged by softener salt in an automatic process called Regeneration During regeneration the unit fi...

Page 3: ...tension cords are not recommended If water pipes are used to ground electrical system you will need to install a jumper wire across the filter unit Unpacking the unit The unit includes Unpack the unit...

Page 4: ...tric turn off the power to it to avoid damage to the element in the tank If you have a private well turn the power off to the pump then shut off the main water shut off valve If you have municipal wat...

Page 5: ...o 3 4 will be required Please follow your local plumbing other applicable codes for where to run softener discharge water NEVER MAKE A DIRECT CONNECTION INTO A WASTE WATER DRAIN A PHYSICAL AIR GAP OF...

Page 6: ...ect the adapter to the power supply NOTE Your unit is not yet ready for service until you complete manual regeneration see pages 7 11 E START UP PROGRAMMING The control valve is controlled with simple...

Page 7: ...ET REGEN again Hour value will be accepted and minute value will start flashing 2 The display will read Press MENU Key for 3 sec to unlock 3 After 3 seconds the display will beep confirming unlock 4 P...

Page 8: ...URRENT DATE AUG 15 2018 16 Now press UP or DOWN key to change the value to current day of the month CURRENT DATE AUG 15 2018 17 Press SET REGEN again Date value is accepted and the YEAR starts flashin...

Page 9: ...more than 2 weeks The system will perform a brief backwash and rinse based on advanced setting The purpose is to keep the water fresh in the softener tank and plumbing system When you return from vaca...

Page 10: ...on 1 Option 2 Option 3 Option 4 Comments 1 System Language English Spanish French Set to French if desired Spanish not enabled 2 Valve Operation Softener Filter Iron Filter Leave at default setting 3...

Page 11: ...l not be lost during a power failure If power fails while the unit is in regeneration the valve will finish regeneration after power is restored If the valve misses a scheduled regeneration due to a p...

Page 12: ...up the bridge Allow at least four hours to produce a brine solution and then manually regenerate the softener This should always be followed up by allowing the unit to use up any remaining salt and t...

Page 13: ...is high 1 Refill time is too high 1 Correct brine refill settings Table 1 D Low water pressure 1 Iron or scale buildup in line feeding softener 2 Iron buildup inside valve or tank 3 Inlet of control v...

Page 14: ...05 05056097 Piston pin 1 A06 05056023 End plug 1 A07 05056070 Quad ring 2 A08 05056024 End plug washer 1 A09 05056022 Piston retainer 1 A10 05056181 Piston electrical 1 A11 05056104 Muffler 1 A12 0505...

Page 15: ...056027 Injector nozzle 1 A34 05056103 Injector screen 1 A35 05056028 Injector throat 1 A36 05056035 BLFC button retainer 1 A37 05056191 BLFC 2 1 A38 05056138 O ring 14x1 8 1 A39 05056100B BLFC fitting...

Page 16: ...e greater than 0 05 ppm 0 05 mg l f Tannins or colour This limited Warranty applies only to a unit when returned to the Warrantor at the owner s expense and in accordance with shipping instructions re...

Reviews: