CHANGING A NOZZLE
1
REMOVING THE NOZZLE RETENTION SCREW
Use your K-Key or a small flat blade screwdriver to remove the nozzle retention
screw by turning counter-clockwise to remove and clockwise to re-install.
2
PULL UP THE RISER
Insert the K-Key in the keyhole on the top of the nozzle turret and turn the
key 1/4 turn to insure that the key does not slip out of the keyhole when
you pull it up. Firmly pull up the entire spring-loaded riser to access the
nozzle socket. Hold the riser assembly up with one hand.
3
REMOVING THE NOZZLE
With the nozzle retention screw removed, insert the K-Key into the slot
directly under the nozzle “prongs” at the top of the nozzle. Now, turn the key
1/4 turn to “hook” the nozzle and pull the nozzle out.
4
INSTALLING A NOZZLE
Press the desired nozzle into the nozzle socket. Make sure the nozzle
number is visible and the nozzle “prongs” are up. Then, re-install the
nozzle retention screw.
NOTE:
The nozzle retention screw is also a
break-up screw and used to adjust the distance of the spray.
SETTING THE ARC ADJUSTMENT
1
FINDING THE LEFT START POSITION
Place your finger on the top center of the nozzle turret. Rotate the turret
to the right until it stops and then back to the left until it stops. Notice the
position of the nozzle arrow. This is the “Left Start” position. The sprinkler
will begin spraying from this position and rotate clockwise until it reaches
the right Adjustable Stop-Return Point.
2
ORIENTING THE LEFT START POSITION
Insert the K-Key in the keyhole on the top of the nozzle turret and turn the
key 1/4 turn to insure that the key does not slip out of the keyhole when
you pull it up. Being careful not to allow the nozzle turret to turn, firmly pull
up the entire spring-loaded riser. Hold the lower riser assembly up with one
hand. Now turn only the lower riser clockwise or counter-clockwise until the
nozzle arrow is pointing where you want the sprinkler to begin spraying.
3
CHANGING THE ARC
Insert the K-Key or a small flat blade screwdriver into the Arc Set Adjustment
slot. Turn clockwise to increase the arc or counter-clockwise to decrease the
arc.
NOTE:
The arc set arrow in the center of the nozzle turret rotates to
show the current setting.
WHEN SET AT 360°, THE SUPER
PRO WILL
ROTATE CONTINUOUSLY IN A CLOCKWISE DIRECTION.
4
OPERATING THE SHUT OFF
To shut off the water flow insert your K-Key into the flow shut-off slot and
turn counter-clockwise. During system operation, the riser will remain
elevated. To open flow again, turn key clockwise.
NOTE:
The
Super
Pro
is factory preset with a 90° arc setting, and includes a pre-installed #2.5 nozzle.
S075 S