S050 S
GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS
CHANGING A NOZZLE
1
REMOVING THE NOZZLE RETENTION SCREW
Use your K-Key or a small flat blade screwdriver to remove the nozzle
retention screw by turning counter-clockwise to remove and clockwise
to re-install.
2
PULL UP THE RISER
Insert the K-Key in the keyhole on the top of the nozzle turret and turn
the key 1/4 turn to insure that the key does not slip out of the keyhole
when you pull it up. Firmly pull up the entire spring-loaded riser to
access the nozzle socket. Hold the riser assembly up with one hand.
3
REMOVING THE NOZZLE
Insert the end of the K-Key, hook side up, into the tall slot along the right
side of the nozzle and pull up to pop out nozzle.
NOTE:
Do not
put the K-Key or any instrument into the nozzle opening.
4
INSTALLING A NOZZLE
Press the desired nozzle into the nozzle socket. Make sure the nozzle
number is visible and the nozzle “Wing” is up. Then, re-install the
nozzle retention screw.
NOTE:
The nozzle retention screw is also a
break-up screw and used to adjust the distance of the spray.
SETTING THE ARC ADJUSTMENT
1
FINDING THE LEFT START POSITION
Place your finger on the top center of the nozzle turret. Rotate the turret
to the right until it stops and then back to the left until it stops. Notice
the position of the nozzle arrow. This is the “Left Start” position. The
sprinkler will begin spraying from this position and rotate clockwise until
it reaches the right “Arc Stop”.
2
ORIENTING THE LEFT START POSITION
Insert the K-Key in the keyhole on the top of the nozzle turret and turn
the key 1/4 turn to insure that the key does not slip out of the keyhole
when you pull it up. Being careful not to allow the nozzle turret to turn,
firmly pull up the entire spring-loaded riser. Hold the lower riser assembly
up with one hand. Now turn only the lower riser clockwise or counter-
clockwise until the nozzle arrow is pointing where you want the sprinkler
to begin spraying.
3
CHANGING THE ARC
Insert the K-Key or a small flat blade screwdriver into the Arc Set
Adjustment slot. Turn clockwise to increase the arc or counter-clockwise
to decrease the arc.
NOTE:
The arc set arrow in the center of the nozzle turret rotates
to show the current setting.
NOTE:
The
S050S
is factory preset with a 40° arc setting, and includes a pre-installed #1.5 nozzle.