Electric Valve

Users manual

2 years w

arranty

RN 150

Summary of Contents for RN 150

Page 1: ...Electric Valve Users manual 2 years warranty RN 150...

Page 2: ...ing stainless steel metering pin Stainless steel diaphragm differential spring for smooth closing PN12 tested piece by piece at 14 bar Bleed handle for manual opening with internal bleed Type 1 Operat...

Page 3: ...pper body where the water exerts its thrust is larger than that of the shutter and therefore the latter is pushed by the unbalanced force and therefore the latter is pushed by the unbalanced forces to...

Page 4: ...Solenoid Mobile Nucleus Manual opening Flow control Adapter Upper Body Spring Diaphragm Ring Lower body O N O F F Exploded view...

Page 5: ...Dimensions 92 00 92 00 141 00 140 00 165 00 114 00 710 00 33 00 116 00 114 00 46 00 710 00 114 00 46 00 710 00 114 00 710 00 26 00 115 00 114 00 114 00 128 00 42 00 710 00 710 00 42 00...

Page 6: ...nually Check that the communi cation hole with the upper body is not clogged Check that the communi cation hole with the upper body is not clogged Check that the voltage at the solenoid is at least 22...

Page 7: ...enoid is properly screwed in Check that the static pressure is below 0 7 bar Check that the movable core seat is clean Check that the movable core seat is clean Check that the plug and lower body mout...

Page 8: ...ng is closed The system pressure upstream of the solenoid valves is greater than 0 7 bar The mobile core slides freely The bore of the diaphragm unit is free The lower body of the solenoid valve has n...

Page 9: ...lacing it RAIN spa shall not be liable for any costs or incidental or consequential damages caused by a defective product RAIN spa s liability under this warranty is limited exclu sively to the replac...