4. Connect the SC932C 9-pin port to the internal enclosure CS I/O port with the ribbon cable
supplied with the enclosure (
5. Wire the RAD modem to the enclosure with the 30 cm (12 in) patch cable. Match wire labels
to wiring panel labels on both the enclosure and the RAD modem (+XMT to +XMT). A
small screwdriver is provided with the enclosure to access the RAD modem connections.
Use the screwdriver to press down on the lever arm.
WARNING:
Pressing too hard on the lever arm can break it!
6.7.3.2 External installation of short haul modem
FIGURE 6-25. Short-haul modem wiring diagram
Components of the short haul kit used for external connections at the WS-PRO2 enclosure are:
(1) 6 m (20 ft) 4-wire patch cable
(2) Direct burial splice kits
(1) User-supplied 22 AWG, REA, PE-86 Filled Buried Wire (supplier: Anixter,
, Anixter pn F-02P22BPN)
Section 6. Installation
40