5
ESP-Me User Manual
Installation
2.
1.
1/8 IN.
Mount Controller
b
NOTE:
Use wall anchors (not included) if needed.
Connect Power
c
WARNING:
DO NOT plug in the transformer or
connect external power until you have completed
and checked all wiring connections.
c
WARNING:
All electrical connections and wiring
runs must comply with local building codes.
Some building codes require that only a licensed
or certified electrician can make the power
connections. Please check with your local building
code for guidance. Only professional personnel shall
install the controller.
Electrical Specifications (230V only)
Input
230VAC, 0.2AMP, 50/60Hz
Output
25.5VAC, 1.0AMP, 50/60Hz
Indoor Model
1.
Route the transformer power cord through the conduit
opening at the bottom left of the unit. Knot the cable/
cord inside the controller cabinet to prevent it from
being pulled out.
d
CAUTION:
Do not route the power cord through the
field wire opening at the bottom right of the unit.
3.
4.
VT MV COM 5 6 7 11 12 13
17 18 19
1 2 3 4
8 9 10 14 15 16 20 21 22
VT MV COM
1 2 3 4
VT = VALVE TEST
CONNECT
120 VAC
VT MV COM 5 6 7 11 12 13
17 18 19
1 2 3 4
8 9 10 14 15 16 20 21 22
VT MV COM
1 2 3 4
VT = VALVE TEST
1.
2
4
VAC
G
ND
S
EN
S
2
4
VAC
G
ND
SEN
S