Page 1: ...InTANK iR2023 User Manual ...

Page 2: ...cedure 3 5 RAID Mode Setting 4 6 Computer Setup 5 7 Hard Disk Status on LCD Screen 6 8 Data Rebuilding Operation 7 9 GUI Monitoring Software and Firmware Update 8 10 Questions Answers 10 InTANK iR2023 產品使用說明 12 1 產品外觀及包裝內容 12 2 環境需求 13 3 硬體需求與注意事項 14 4 硬體安裝 14 5 設定 RAID 層級 15 6 電腦設定 16 7 訊息顯示 17 8 資料重建功能說明 18 9 GUI 功能說明與韌體更新 19 10 常見問題 21 iR2023 User Manual V1 0 ...

Page 3: ... is subjected to change without prior notifications If you have any question regarding to the product you purchased or you would like to know the latest product information User Manual s update please contact to your local supplier or visit to www raidon com tw for further information Copyright Raidon Technology Inc All right is reserved Open the package and you should find the following parts iR2...

Page 4: ... HDD Idle Blue light always on Blue light always on Blue light always on N A Access Blue light flashing Purple light flashing Blue light always on N A Rebuilding Source Blue light always on Blue light always on Blue light always on N A Rebuilding Target Blue light always on Red light flashing Blue light always on N A Fan Failure Blue light always on Blue light always on Purple light always on ON 7...

Page 5: ... hard drives to set the drive mode will result in complete data loss If you must change the drive mode make sure to backup all data prior to the mode change 6 A reboot is required after adding or changing RAID mode to ensure that the update is completed to the new RAID mode 7 iR2023 product allows user to simultaneously use the two different hard drives from two different manufactures However if t...

Page 6: ...es hardware status monitoring to industrial control system or IPC via RS232 If more information are required please contact supporting raidon com tw SATA SATA SATA Cable SATA Power Cable Internal host shell schematic 1 2 iR2023 iR2023 Power on your system after hardware installation is completed and your operating system will automatically detect the hard drives from booting Then follow the steps ...

Page 7: ...mpletely finished The user can freely retrieve and save data to iR2023 just like retrieving and saving data to a regular hard drive If the user has any problem during the operation please refer to the Question Answer Q A section in Appendix 2 RAID 0 mode 1 Place two new hard drives into iR2023 We would strongly suggest you to use two identical hard drives to get the maximum memory capacity And if ...

Page 8: ...normal RAID 1 degraded Pri M Sec O 5 RAID 1 Failure Primary and secondary hard drives are failure RAID 1 failure Pri M Sec M 6 RAID 1 Failure Double Source RAID 1 failure Double Source 7 RAID 0 Failure Primary hard drive is missing but secondary hard drive is normal RAID 0 failure Pri M Sec O 8 Rebuilding Rebuilding Sec Pri 32 1 Booting and Normal status RAIDON RAIDbox2 RAID 1 vxxxxxx x Pri HDD OK...

Page 9: ...n remove the failed hard drive from the system while the system is still in operation without shutting down the machine If the failed hard drive is replaced shortly the system will automatically execute the Auto Rebuilding function without affecting the system operation and also any operation command from the user When the iR2023 detects one hard drive missing or failure the Buzzer starts BEEPING ...

Page 10: ...re Upfrade You may update the Firmware via this GUI to just simply click on the Load button to locate the firmware file to proceed After completing the update you may restart the power to work with the new firmware Caution Any random firmware update may cause the malfunction at your iR2023 We strongly recommend you not to change upgrade iR2023 firmware if still works properly 9 GUI Monitoring Soft...

Page 11: ... completing the configuration click on the OK button to save Device must be in the operation states during configuration works 3 2 HDD Failure Device Removed 1 Insert your e mail address as the receiver for notification and click on to add the e mail address onto the Notification List Maximum up to 10 e mail addresses 2 Key in the Subject title and contents in the columns of Subject and Contents 3...

Page 12: ...orting raidon com tw Computer works fine but iR2023 doesn t perform right in reading writing messagesproperly Please first check whether if iR2023 is executing the auto REBUILDING work If it works for REBUILDING your iR2023 is a good device And if it doesn t please follow the following two ways to find out the possible root cause 1 Please examine if your SATA cable is too long and will attenuate s...

Page 13: ...ll happen if we turn off the computer power while iR2023 is still executing auto REBUILDING work Under the Mirror mode RAID 1 if computer power is off during REBUILDING work iR2023 will still remember the percentage of its REBUILDING work and then resume it back to its REBUILDING work while computer power is back on Is it possible to lose data during the REBUILDING work The REBUILDING work will au...

Page 14: ...時為準 任何產品規格或相關資訊更新請您直接到 www raidon com tw 網站查詢 本公司將不另行通知 若您 想獲得 RAIDON 最新產品訊息 使用手冊 韌體或對 RAIDON 產品有任何疑問 請您聯絡當地供應 商或到 www raidon com tw 取得相關訊息 本手冊相關產品內容歸銳銨科技股份有限公司版權所有 打開包裝外盒後 包裝內容應包含下列組件 iR2023 iR2023 產品本體 x1 內含抽取盒 x3 SATA 連接線 x1 螺絲及鑰匙 快速安裝導引 x1 InTANK iR2023 產品使用說明 請確認相關配件與產品本身是否有受損或配件缺少 若有任何疑問請與本產品供應商聯絡 請前往官網 www raidon com tw 下載驅動程式以及其餘相關資源 ...

Page 15: ...SATA 15Pin 電源輸入埠 6 SATA 7Pin 資料連接埠 RAID 硬碟 狀態 獨立硬碟指示燈 RAID 硬碟指示燈 電源 故障顯示燈 蜂鳴器 無硬碟 N A 紅燈恆亮 紫燈恆亮 鳴叫 待機 藍燈恆亮 藍燈恆亮 藍燈恆亮 N A 資料存取 藍燈閃爍 紫燈閃爍 藍燈恆亮 N A Rebuilding Source 藍燈恆亮 藍燈恆亮 藍燈恆亮 N A Rebuilding Target 藍燈恆亮 紅燈閃爍 藍燈恆亮 N A 風扇故障 藍燈恆亮 藍燈恆亮 紫燈恆亮 鳴叫 6 電源 故障顯示燈 7 硬碟抽取盒把手 8 頂出按鍵 9 硬碟抽取盒鎖 10 硬碟讀寫燈 2 環境需求 工作溫度 0 40 32 104 儲存溫度 10 70 o C 14 158 o F 工作電壓 5V DC ...

Page 16: ...SATA III 介面 2 具備 SATA I SATA II 或 SATA III 介面的硬碟 3 最上方的獨立硬碟無法與主 次硬碟共同設定 RAID 模式 為功能獨立的硬碟 4 強烈建議使用 iR2023 前先設定好 RAID 模式 預設值是 RAID 1 5 一旦使用模式確認後 使用相同的硬碟進行模式切換將會導致資料遺失 如果需要進行模式變更 請於變更前先進行資料備份 6 在新增或變更 RAID 模式後需重新啟動 以確保完成更新為新的 RAID 模式 7 本系統允許使用不同廠牌的硬碟 但如果要獲得更好的效能 我們強烈建議使用相同廠牌型號的硬 碟 8 安裝硬碟前請先確認所使用的硬碟並無壞軌或是其他問題 以免導致系統損毀或資料遺失 9 硬碟格式化後 iR2023 的總使用儲存容量或許會與硬碟容量加總後的有所不同 10 強烈建議除了使用 iR2023 的資料儲存功能外 請針對重要資料備份到...

Page 17: ...AID 1 模式 1 將兩顆新的硬碟放入 iR2023 中 強烈建議您使用兩顆相同的硬碟 以便取得對等的容量 如果 兩顆硬碟的容量不同 iR2023 將會以小容量的硬碟為依據 2 RAID 1 模式下 兩顆硬碟是鏡射關係因此擁有相同的資料 因此有一顆硬碟損毀仍然可以正常運 作 當放入新硬碟取代損毀硬碟後 系統會自動將資料重建到新的硬碟 2 RAID 0 模式 1 將新的硬碟放入 iR2023 中 強烈建議您使用兩顆相同的硬碟 以便取得對等的容量 如果兩顆 硬碟的容量不同 iR2023 將會以小容量的硬碟為依據 2 RAID 0 模式下 兩顆硬碟的容量會被加總成一個大儲存容量 並且提供更佳的存取效能 Note 1 RS232 埠與 RS232 線 提供工控系統或是工業電腦透過 RS232 監控硬碟狀態 2 我們不建議使用者在未經授權的情況下自行拆卸系統 如未經授權自行拆卸所導致的損毀將不在保...

Page 18: ...設定 當 iR2023 的硬體安裝完成 即可準備進行開機動作 硬體安裝完成後 將 BIOS 的硬碟偵測設定為自動 iR2023 將會被視為如同一顆硬碟一般 當電腦開 機後 系統會顯示下列偵測訊息 1 安裝在 iR2023 中的硬碟能夠被 Windows 的裝置管理員偵測到 2 使用 iR2023 前 使用者可以透過磁碟管理選擇硬碟的格式 到此完成整個安裝程序 使用者可以如同存取一般硬碟般的使用 iR2023 如果使用上仍有問題 請參 閱附件的 Q A ...

Page 19: ...i 硬碟損毀而 Sec 硬碟仍然可正常存取 RAID 1 degraded Pri M Sec O 5 RAID 1 損毀 Pri 與 Sec 硬碟皆損毀 RAID 1 failure Pri M Sec M 6 RAID 1 損毀 Source 碟重複 RAID 1 failure Double Source 7 RAID 0 損毀 Pri 硬碟遺失而 Sec 硬碟仍然正常 RAID 0 failure Pri M Sec O 8 資料重建 Rebuilding Sec Pri 32 1 開機與正常待機狀態 RAIDON RAIDbox2 RAID 1 vxxxxxx x Pri HDD OK Sec HDD OK ...

Page 20: ...CD 顯示幕與監控軟體發出警示 使用者可以在系統 仍在運作下 無需關掉機機器即可將損毀的硬碟取出 一但替換損毀硬碟後 iR2023 即會在不影響系 統運作的情況下自動開始進行資料重建 使用者也無需對 iR2023 下任何指令 當 iR2023 偵測到硬碟遺失或是損毀 蜂鳴器會啟動 LCD 螢幕會顯示以下訊息 當移除損毀的硬碟並替換一顆新硬碟後 如果新硬碟有正確安裝 LCD 螢幕會顯示以下訊息 安裝新硬碟後幾秒鐘 LCD 螢幕會顯示資料重建的進度 當資料重建完成後 LCD 螢幕會顯示以下訊息 8 資料重建功能說明 Pri HDD OK Sec HDD OK RAID 1 degraded Pri X Sec O Pri HDD OK Sec HDD Insert Rebuilding Sec Pri 32 Pri HDD Insert Sec HDD OK Rebuilding Pri Se...

Page 21: ...anual 19 使用者可以從網站下載來安裝 GUI 軟體 藉此監控產品的狀態 1 系統狀態 GUI 會自動偵測 iR2023 並且顯示相關資訊 2 韌體升級 使用者可以透過此 GUI 進行韌體升級 只需簡單的點選 Load 指定韌體檔案位置後即可進行升級 升級過程或許需要重新啟動系統來完成整個升級程序 注意 任意更新韌體有可能導致系統運作不正常 強烈建議如果系統運作正常情況下不要進行韌體升級 9 GUI 功能說明與韌體更新 ...

Page 22: ... mail 相關名稱與完整位置 以及 SMTP 的相關資訊 2 如果需要密碼 請勾選 SMTP Login Authentication 並輸入密碼 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 3 2 硬碟損毀 裝置被移除 1 在 E Mail Address 欄位填入要收取通知的 e mail 點選 即可增加另一組 最多可填 入 10 組 e mail 2 在 Subject 與 Contents 填入 e mail 訊息的主旨與內容 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 ...

Page 23: ...還是無法正常開機 這有可能是因為硬體上的相容性問題 如果是硬體 上相容性問題 請連繫我們的客服部門 使用時 電腦運作正常但是 iR2023 的存取效能不正常 請確認 iR2023 是否正在資料重建 1 請確認所使用的連接線長度 是否所使用的 SATA 線太長以及是否合乎標準規範 2 如果線材的長度與規格都沒問題 請關閉 iR2023 並取出其中的硬碟 直接接硬碟連接到電腦 並進行檢測 有可能是硬碟中的壞軌導致 RAID 1 模式下 如果放入一顆新的硬碟 系統的總容量會是 1 iR2023 的總容量是依據一開始安裝的主硬碟容量而定 2 安裝完成後 即使更換一顆較大容量的硬碟 儲存容量也不會增加 為何當我安裝第二顆硬碟時出現錯誤訊息 第二顆硬碟的容量必須大於第一顆硬碟 否則 iR2023 不會進行資料重建 10 常見問題 Q1 A Q2 A ...

Page 24: ...重建時關掉電腦電源 會不會怎樣 在 RAID 1 模式下資料重建過程中關閉電源 控制器會自動記憶已完成的百分比 當再度開啟電 源後 重建過程會從斷電前的百分比繼續 資料重建過程中是否有可能會遺失資料 資料重建功能是 Sector to Sector 的拷貝方式 技術上來說 資料並不會在資料重建過程中遺失 但是 如果資料重建過程中 原本的硬碟 Source 被偵測到壞軌 iR2023 將會採用模擬方式而 不會因此壞軌認為硬碟損毀 因此 這種情況下儲存在壞軌的資料就有可能會遺失 Q1 A Q2 A ...

Page 25: ...iR2023 User Manual 23 www raidon com tw ...