Symptom
Corrective Action
Craft will not plane
•
Change the Trim Angle of the Motor by
moving/changing the Thrust Rod position.
•
Check for proper craft inflation.
•
Adjust craft load distribution.
•
Check fuel supply.
Noise in Safety Jet
•
Remove motor from water.
•
Inspect pump for foreign objects.
•
Inspect Captive Screws for tightness.
•
Remove, Impeller check Stater Bolt Torque
Settings.
Knock in Lower Unit at idle speeds
•
This is normal and caused by the shifter
spring movement against Propeller Shaft
Assembly.
Cavitation
•
Reduce Speed and secure motor.
•
Change the Trim Angle of the Motor by
moving/changing the Thrust Rod position.
•
Tilt the motor up and check for damage to
the Safety Jet.
•
Check for bio matter, or debris caught in the
stator.