889-3819-00
MMU2-1600GE series Operations Manual Rev Apr 2020 Page
47
of 51
3 S
OC S
O
C
C
5 G
C
6
8
6 O
9
S O S
0
O O 3
O O
S
S C O
S U
O S C
G S
O 5 S C 5
S CC
CO G
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
R Y G W
1/4 AMP SLO BLO
CONFLICT
CVM / WD
24V-1
24V-2
SHORT CLR
SHORT YEL
PORT 1 FAIL
RED FAIL
DUAL IND
FIELD CHK
PRGM CARD
LOC FLASH
POWER
TYPE 12
RECEIVE
TRANSMIT
DIAG FAIL
C
O
M
M
4.6.6.6
DIAGNOSTIC STATISTICS MENU
MENU TEXT
MENU FUNCTION
SDLC STATS
View SDLC statistics.
COM PORT STATS
View Com port statistics.
ETHERNET PORT STATS
View Ethernet port statistics.
DC PROCESSOR COM STATS
View DC Processor communication statistics.
SPEED STATS
View various performance statistics.
4.6.6.6.1
SDLC STATISTICS
This display shows the number of frames transmitted (TX FRMS), number of frames received (RX FRMS), total
number of frames received with errors (RX ERRS), number of frames received with buffer overrun errors
(OVERRUN), number of frames received with buffer overflow errors (OVERFLW), number of frames with
framing errors (FRAMING), number of very short frames received (V SHORT), number of short frames received
(SHORT), number of long frames received (LONG), number of frames received with the incorrect control byte
(CONTROL), number of frames received with a CRC error (CRC), and number of frames aborted (ABORT). This
display is view only. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.6.6.2
COMM PORT STATISTICS
This display shows the number of bytes transmitted (TX BYTES), number of bytes received (RX BYTES), number
of buffer overrun errors (OVERRUN), number of framing errors (FRAMING), number of procedure faults (PROC
FLT), number of breaks received (BREAKS), number of parity errors received (PARITY), number of frames
received with a checksum error (CHKSUM), number of start of frame errors (SOF), and number of end of frame
errors (EOF). This display is view only. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.6.6.3
ETHERNET PORT STATISTICS
This display shows the number of bytes transmitted (TX BYTES), number of bytes received (RX BYTES), number
of buffer overrun errors (OVERRUN), number of framing errors (FRAMING), number of procedure faults (PROC
FLT), number of breaks received (BREAKS), number of parity errors received (PARITY), number of frames
received with a checksum error (CHKSUM), number of start of frame errors (SOF), and number of end of frame
errors (EOF). This display is view only. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.6.6.4
DC PROCESSOR COMMUNICATION STATISTICS
This display shows the number of bytes transmitted (TX BYTES), number of bytes received (RX BYTES), number
of buffer overrun errors (OVERRUNS), number of framing errors (FRAMING), number of breaks received
(BREAKS), and number of parity errors received (PARITY). This display is view only. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.6.6.5
SPEED STATISTICS
This display shows the current number of samples taken for every AC inputs every line cycle, number of code
bytes checksummed each second, and the number of RAM Bytes Tested per Second. This display is view only.
Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.6.7
FACTORY DIAGNOSTICS
The features and data accessible within the Factory Diagnostics menu and submenus are intended for use by
qualified Test and Technical Support personnel only. Should the need arise, the user will be instructed on the
correct use of these features and data.
4.7
FRONT PANEL LED INDICATORS
The monitor has 77 light emitting diodes (LEDs) that are used to convey
information to the user. These LEDs are color coded to increase viewability
and enhance the intuitiveness of the display. The LEDs are extremely bright to
allow viewing of the front panel indicators in direct sunlight. The front panel
display is updated every 16 milliseconds.
The front panel display is broken up into four logical groups: Field Status,
Power / Type, Transmit / Receive, and Fault.
4.7.1
FIELD STATUS INDICATORS
There are 60 field status indicators, one for each field input defined by the TS 2
specification for Type 16 and Type 12. The display is logically organized into
four columns and sixteen rows. The columns are labeled
R
for Red,
Y
for
Yellow,
G
for Green, and
W
for Walk. The rows are numbered from
1
to
16
,
corresponding to the channel numbers for Type 16 and Type 12.
The indicator for a field input will be on if the RMS voltage over the last 33 milliseconds (two cycles of AC
power) is above the threshold for that type of input. (See Section 3.2 for the voltage levels for each type of input.)