889-3819-00
MMU2-1600GE series Operations Manual Rev Apr 2020 Page
42
of 51
or remove. It will only warn you that the current jumpers do not match the expected jumpers for a standard dual
ring configuration with the channel assignments given to the wizard.
4.6.2.1.10.3
ALMOST DONE
If there were no warning or you ignored all warnings, you will get the Almost Done screen. Pressing ENTER here
will create a new configuration based on the information provided. This new configuration is not saved. It is the
pending configuration. The user should confirm that the settings created by the wizard are appropriate for the
actual intersection.
4.6.2.2
GENERAL SETTINGS
MENU TEXT
MENU FUNCTION
LOGGING THRESHOLDS
View and/or edit the AC Logging Threshold settings of high voltage alarm,
low voltage alarm, and power interrupt duration.
USER UNIT INFORMATION
View and/or edit the Location text, Unit ID, and Agency ID.
FACTORY UNIT INFORMATION
View the Model Number, Serial Number, and Manufacture Date.
COM PORT SETTINGS
View and/or edit the Com port baud rate, stop bits, and parity settings.
ETHERNET SETTINGS
View and/or edit the Unit IP address, Unit IP Port, and Gateway IP address.
4.6.2.2.1
AC LOGGING EVENTS
These settings affect the entries made to the AC Line log. Use the up (▲) or down (▼) pushbutton t
o navigate
between the settings. Use the left (◄) or right (►) to change the highlighted setting. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
HIGH VOLTAGE – The AC high voltage alarm threshold setting can be user configured from
98V
to
135V
in one
volt increments. The recovery voltage is automatically set to three volts lower than the alarm voltage. The factory
default for this setting is
130V
.
LOW VOLTAGE – The AC low voltage alarm threshold setting can be user configured from
98V
to
135V
in one
volt increments. The recovery voltage is automatically set to three volts higher than the alarm voltage. The factory
default for this setting is
105V
.
POWER INT – The Power Interrupt interval setting can be user configured from
17MS
to
500MS
in 16.66
millisecond increments (rounded up or down to the nearest whole number). The factory default for this setting is
100MS
.
4.6.2.2.2
USER UNIT INFORMATION
See Section 4.6.1.1
4.6.2.2.3
FACTORY UNIT INFORMATION
See Section 4.6.1.2
4.6.2.2.4
COMM PORT SETTINGS
Use the left (◄) or right (►) pushbutton to navigate to the desired setting to change. Use the up (▲) or down (▼)
pushbutton to change the highlighted setting. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit to
the previous display.
BAUD RATE – The Communications Port Baud Rate setting can be set to any of the following values:
300
,
1200
,
2400
,
4800
,
9600
,
19200
,
38400
, or
57600
. The factory default setting is
57600
.
STOP BITS – The Communications Port Stop Bits setting can be set to
1
or
2
. The factory default setting is
1
.
PARITY – The Communications Port Parity setting can be set to
NONE
,
ODD
, or
EVEN
. The factory default
setting is
NONE
.
4.6.2.2.5
ETHERNET SETTINGS
See Section 4.6.1.3
4.6.3
LOGGING SYSTEM
MENU TEXT
MENU FUNCTION
VIEW LOGS
View monitor logs.
CLEAR LOGS
Clear individual logs.
CLEAR ALL LOGS
Clear all logs.
LOGGING THRESHOLDS
View and/or edit the AC Logging Threshold settings of high voltage alarm, low
voltage alarm, and power interrupt duration.