MMU2-1600GE series Operations Manual Rev Apr 2020 Page
31
of 51
Press the
ESCAPE
pushbutton to move backward through the menu selections. The monitor will automatically
select the item on the menu that was just exited as a reminder of where you have been.
MENU TEXT
MENU FUNCTION
IDENTIFICATION INFORMATION
View and/or edit the identifying information of user unit information, factory unit
information, and Ethernet settings.
CONFIGURATION SETTINGS
View and/or edit the configuration settings of the monitor.
LOGGING SYSTEM
View and/or clear monitor logs.
DATE & TIME SETTINGS
View and/or edit the monitor date and time, daylight saving settings, and monitor uptime.
REAL TIME MONITOR STATUS
View all inputs to the monitor. These include field voltages, AC line voltage, Red Enable
Voltage, temperature, Port 1 errors, all DC input voltages, and watchdog timings.
DIAGNOSTIC INFO
Initiate certain diagnostic procedures or to view diagnostic information.
4.6.1
IDENTIFICATION MENU
MENU TEXT
MENU FUNCTION
USER UNIT INFORMATION
View and/or edit the Location text, Unit ID text, and Agency ID text.
FACTORY UNIT INFORMATION
View the Model Number, Serial Number, and Manufacture Date of the monitor.
ETHERNET SETTINGS
View and/or edit the Unit IP address, Unit IP Port, and Gateway IP address for this
monitor. These settings can still be set even if the unit does not support Ethernet.
4.6.1.1
USER UNIT INFORMATION
Use the up (▲) or down (▼) pushbuttons to navigate between the fields on the display. A flashing character will
indicate the currently selected character position. Use the left (◄) or right (►) pushbutton to select the desired
character position. Press the
ENTER
pushbutton to enter the data entry mode. Use the left (◄) or right (►)
pushbutton to select the desired text character and press the
ENTER
pushbutton to accept and store the character
selected. Press the
ESCAPE
pushbutton to save the data on this display and exit to the previous display.
LOCATION – This text field is 40 characters long. The user can edit this field. This field is typically used to store
the intersection that the monitor is installed at (example: VIRGINIA AVE. & LONGLEY AVE.)
UNIT ID
– This text field is four (4) characters long. The user can edit this field. This field is typically used to
store a unique intersection ID assigned by the agency maintaining the intersection.
AGENCY ID – This text field is five (5) characters long. The user can edit this field. This field is typically used to
store an agency ID. This can very useful when an agency or contractor provides maintenance services for more
than one agency.
4.6.1.2
FACTORY UNIT INFORMATION
This screen is read only and therefore there will be no cursor displayed on this screen. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
MODEL NUMBER – This text field is 20 characters long. The user cannot edit this field.
SERIAL NUMBER – This text field is 8 characters long. The user cannot edit this field.
MANUFACTURE DATE – This is a date field. The user cannot edit this field. This is the date that the monitor
passed final quality testing.
4.6.1.3
ETHERNET SETTINGS
Use the left (◄) or right (►) pushbutton to select the field to change. Use the up (▲) or down (▼) pushbutton to
change the highlighted value. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to save the data on this
display and exit to the previous display. These values can be edited even if the Ethernet option is not installed on
the unit.
UNIT IP – The Unit IP address can be user configured from 0.0.0.0 to 255.255.255.255. The factory default
setting is 0.0.0.0. Consult your Network Administrator for appropriate values for your network.
UNIT IP PORT – The Unit IP Port can be user configured from
00000 to 65535.
The factory default setting is
10001. The factory default should be used unless your Network Administrator deems that a different port is
desired for routing purposes.
GATEWAY IP – The Gateway IP address can be user configured from 0.0.0.0 to 255.255.255.255. The factory
default setting is 0.0.0.0. This field is to support future features and currently is not used.