889-3819-00
MMU2-1600GE series Operations Manual Rev Apr 2020 Page
23
of 51
3.3
TIMING FUNCTIONS
S
TART
D
ELAY
:
................................................................................................................... 2.0 sec (±0.5 sec)
M
INIMUM
F
LASH
:
................................................................................................................ 6 to 16 sec (±1 sec)
P
ORT
1
F
AIL
:
Typical ............. 300 msec
F
IELD
C
HECK
F
AIL
:
Typical ........... 1000 msec
C
ONFLICT
:
No Fault ......... < 200 msec
Detect ......... > 450 msec
Typical ............. 300 msec
R
ED
F
AIL
:
No Fault ......... < 700 msec
Detect ......... > 1000 msec
Typical ............. 800 msec
CVM
F
AULT
:
No Fault ......... < 125 msec
Detect ......... > 175 msec
Typical ............. 150 msec
+24
VDC
M
ONITOR
:
No Fault ......... < 125 msec
Detect ......... > 175 msec
Typical ............. 150 msec
C
LEARANCE
F
AIL
:
No Fault ......... < 2.8 sec
Detect ......... > 2.6 sec
Typical ................. 2.7 sec
D
UAL
I
NDICATION
:
No Fault ......... < 300 msec
Detect ......... > 800 msec
Typical ............. 500 msec
MONITOR
P
OWER
F
AIL
:
Ignore ............. < 450 msec
Respond ...... > 500 msec
Typical ............. 483 msec
F
LASHING
D
ON
’
T
W
ALK
: Flashing if state changes are > 200 msec and < 600 msec
Typical ............. 500 msec
No Fault ......... < 1400 msec
Respond ...... >1600 msec
Typical ........... 1500 msec