APSolute Vision Installation and Maintenance Guide
Specifications
74
Document ID: RDWR_APSV_V400_IG1808
APSolute Vision ODS-VL2 Platform Specifications
Certifications
Safety: EN 60950-1:2006, CB - IEC 60950-1, cTUVus, CCC, cULus
EMC: CE - EN 55022
,
EN 55024, EN 61000-3-2, EN 61000-3-3, IEC
61000 4-2 to 4-6, IEC 61000 4-8 and IEC 61000-4-11, FCC Part 15B
Class A, ICES-003, VCCI Class A, C-Tick
RoHS 6 Compliant
Table 6: General Specifications of APSolute Vision ODS-VL2 Physical Platform
Item
OnDemand Switch VL2
Processor
1 Intel quad-core CPU
Hard disk
Yes
RAM
Up to 32 GB
CompactFlash
1 GB
Physical ports—general
2 x 10 GbE SFP+
8 x 1 GbE RJ45
USB port
Yes
LCD screen
No
RS-232 console
RJ-45 Serial Connection
Dimensions
Width: 436 mm (17.1 in)
Depth: 406 mm (16 in)
Height: 44 mm (1.7 in/1U)
EIA Rack or Standalone: 482 mm (19 in)
Weight
6 kg (13.2 lbs.)
Environmental
Operating temperature: 0 ºC to 40 ºC (32 ºF to 104 ºF)
Humidity: 5% to 95% non-condensing
Auto-range supply
AC: 100-240 V, 47-63 Hz
DC: -36~-72 V
Power consumption
140 W
Heat dissipation
480 BTU/h
CPU temperature
SNMP traps are sent in response to high temperatures:
•
Warning: 74 ºC
•
Critical: 81 ºC
Note:
When the platform reaches the critical temperature, it will
automatically shut down.
Table 5: General Specifications of APSolute Vision ODS-VL Physical Platform
Item
OnDemand Switch VL